RLC dynamics and Laplace circuit models
Two independent storage states usually produce a second-order response. Start with the circuit equations to identify damping, initial slope and forcing. General system performance measures belong to Control Systems; this chapter keeps the electrical solutions.
6.1 RLC equations and natural modes
Past papers · EC 2020–2026 (7 papers): 2 questions, 3 marks
For a series RLC circuit driven by voltage , use state with series current . For a parallel RLC driven by current , use node voltage and inductor current .
For the series circuit, the state equations are and . They give the state matrix for state vector ; its entries have the required derivative/state units, not one common unit.
Critical series resistance is ; critical parallel resistance is . Increasing series resistance increases damping; increasing shunt resistance decreases it.
6.2 Series step response and peak
Past papers · EC 2020–2026 (7 papers): 1 question, 2 marks
Use an initially unenergised series RLC circuit driven by , with output across . Let and .
For a current source feeding in parallel with a series – branch, the branch current obeys . For an initially unenergised current step, the normalised response is the same as above. This follows by substituting into .
Original comparison of second-order capacitor step responses, using dimensionless time.
6.3 Laplace element models and initial energy
Use the unilateral transform from so initial stored energy appears explicitly. is complex frequency in s. Transform definitions and general inversion theory: see Engineering Mathematics.
Write KCL or KVL with these relations, solve the resulting algebraic equations, then invert. A transfer function sets initial energy to zero; a total response must retain it. Capacitor voltages and inductor currents are useful state variables, but capacitor-only loops and inductor-only cutsets can make them dependent. Obtain state derivatives directly from KCL and KVL rather than counting elements blindly.
6.4 Circuit transforms, residues and end values
Let be input voltage transform and the series-element voltage transforms. All following transfer ratios use zero initial energy.
For circuit inversions, , and . A delay factor shifts the causal waveform by seconds. Determine the complete initial state before using these pairs.
Last-minute recall
- Use for series damping and for parallel damping.
- A repeated pole requires a term.
- Initial slope comes from physical circuit equations.
- Capacitor and resistor voltage peaks occur at different instants.
- Laplace initial-source signs follow the PSC derivative laws.
- Transfer functions use zero initial energy.
- Final-value substitution is invalid for an undamped LC oscillation.