Resonance and quality factor
Resonance means zero input reactance or zero input susceptance at a positive frequency. In ideal series or parallel RLC networks this also gives an extremum of the driven response. Loss in a coil can separate these frequencies.
7.1 Series resonance
Past papers · EC 2020–2026 (7 papers): 2 questions, 2 marks
Drive a series with a constant RMS voltage magnitude. Let be the total series loss and .
Below resonance the input is capacitive; above it inductive. The inductor and capacitor voltages cancel as phasors, even when each greatly exceeds source voltage. The peak of capacitor-voltage gain need not occur at .
7.2 Bandwidth and half-power frequencies
Past papers · EE 2020–2026 (7 papers): 1 question, 1 mark
For a voltage-driven series RLC, half power means resistor power falls to half its resonance value. Thus , not one-half.
Series resonance with the exact half-power points; frequency is normalised by the resonance frequency.
7.3 Parallel resonance and coil loss
Distinguish a resistor across ideal from resistance in series with the inductor. These topologies have different resonance formulas.
7.4 Component loss and resonant voltage peak
Past papers · EE 2020–2026 (7 papers): 1 question, 1 mark
A component quality factor compares its reactance magnitude to its series resistance at the specified frequency. Equivalent series and parallel losses are frequency-specific.
Last-minute recall
- Identify whether loss is series or shunt.
- is quality factor; is reactive power.
- The half-power current is of its peak.
- Resonance is the geometric mean of the ideal half-power frequencies.
- Convert bandwidth from rad/s to Hz with .
- A lossy-coil zero-susceptance point need not maximise impedance magnitude.
- Resonant capacitor voltage is not generally largest at current resonance.