Magnetically coupled circuits
Dot marks encode relative winding polarity. Work from signed voltage and current references before applying a series or parallel shortcut. Geometry and magnetic-field derivations belong to Electromagnetic Fields and Waves.
9.1 Dot convention, coupling and energy
Past papers · EE 2020–2026 (7 papers): 2 questions, 4 marks
Choose each voltage positive at the dot and each current entering the dot. Let be self-inductances (H), mutual inductance (H), and the dimensionless coupling coefficient.
Original dot-reference sketch: both current references enter dots, and both voltage references are positive at dots.
9.2 Equivalent inductance and reflected impedance
Past papers · EE 2020–2026 (7 papers): 2 questions, 4 marks
For a two-terminal series connection, the same current enters both dots (aiding) or enters one dot and leaves the other (opposing). Parallel coils have the same voltage polarity across their external terminals.
9.3 Ideal transformer as a circuit element
The ideal transformer is the lossless voltage/current ratio limit with negligible magnetising current. Perfect coupling alone, at finite magnetising inductance, is not enough to impose its current ratio.
Last-minute recall
- Currents entering both dots give positive mutual terms.
- Nonnegative energy requires .
- Reversing one winding reference reverses the cross term.
- Series aiding adds ; opposing subtracts it.
- A shorted secondary reduces primary input inductance.
- An ideal transformer reflects impedance by the square of turns ratio.