Chapter 7

Pumps and pump characteristicsME

A pump supplies energy to liquid so that the operating flow meets a system head requirement. Distinguish the impeller's Euler head, the measured pump head and the shaft input; losses separate all three.

7.1 Pump head and efficienciesME

Use s and d for suction and delivery measuring sections. The manometric head is a rise in total mechanical head across the pump, not merely a pressure difference.

7.2 Centrifugal impeller and starting headME

The inlet triangle for shock-free entry aligns relative velocity with the blade. For zero inlet whirl, tan⁡β1=−U1/Vm1\tan\beta_1=-U_1/V_{m1} under our signed angle convention. At outlet, use the tangential backsweep angle β2t\beta_{2t} from Section 4.2.

7.3 Operating point, control and combined pumpsME

The operating point is the intersection of pump head with required system head. The best efficiency point is the maximum of the pump's efficiency curve, and need not coincide with that intersection. A radial centrifugal pump commonly has falling head and a peaked efficiency curve; axial-pump input power can be high near shutoff.

Throttling a delivery valve increases system resistance and usually lowers flow. Changing speed moves the pump curve according to the affinity laws of Section 6.5. At fixed diameter, a speed change does not generally move the system intersection to the homologous point if static head is nonzero. For a simple flow-inertia model, a local intersection is stable if the slope of Hp−HsysH_p-H_{\rm sys} with respect to QQ is negative.

An original illustrative pump-system intersection and its best efficiency region.An original illustrative pump-system intersection and its best efficiency region.

7.4 Suction head and cavitationME

NPSH is the absolute total suction head above the liquid's vapour-pressure head, referred to the stated pump datum. Available NPSH belongs to the installation; required NPSH belongs to the tested pump at a stated flow and speed.

7.5 Positive-displacement pumpsME

A reciprocating pump displaces nearly a fixed liquid volume per stroke. A relief path is essential if delivery is blocked. Slip is the difference between theoretical swept flow and actual delivery; it is not the same phenomenon as impeller slip.

An air vessel stores and releases liquid so that most of the long pipe carries nearly steady flow, reducing acceleration pressure and friction loss. For an ideal single-acting pump and a pipe segment carrying the mean flow, Vˉpipe=(A/Ap)ωrc/π\bar V_{\rm pipe}=(A/A_p)\omega r_c/\pi. The short pipe between cylinder and vessel still carries pulsating flow.

Last-minute recall

  • Pump manometric head includes pressure, velocity and elevation changes.
  • Shaft input exceeds delivered hydraulic power.
  • Priming establishes a liquid-filled pump and suction path.
  • Series adds head at equal flow; parallel adds flow at equal head.
  • A system intersection must be recomputed after changing speed or pump arrangement.
  • Available NPSH uses absolute pressure and suction-line losses.
  • Reciprocating slip concerns delivered volume; centrifugal slip concerns exit whirl.
  • Acceleration head peaks at stroke ends, where simple-harmonic piston speed is zero.

Revise offline: the whole Turbomachinery handbook as one PDF

46 pages · 1.8 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections