Chapter 9

Compressor–turbine matchingAE

Matching finds a common operating state for components on the same spool. The compressor and turbine must satisfy speed, mass-flow, power and pressure compatibility simultaneously; choosing their maximum efficiencies independently does not establish a match.

9.1 Corrected map coordinatesAE

Let p0i,T0ip_{0i},T_{0i} be the total conditions at the inlet of the component whose map is being read. Reference values pref,Trefp_{\rm ref},T_{\rm ref} are fixed map conventions. A compressor and turbine on one shaft have equal physical rpm, but their corrected speeds differ when their inlet temperatures differ.

The common map definitions are in Section 3.4. Use identical reference temperatures when comparing the two corrected-speed values below.

9.2 Mass, speed and shaft-power compatibilityAE

Past papers · AE 2020–2026 (7 papers): 2 questions, 3 marks

Use engine stations 02 at compressor inlet, 03 at compressor outlet, 04 at turbine inlet and 05 at turbine outlet. Here the leading 0 denotes total conditions, not a separate station. For combustion and fuel-flow balances, see the Thermodynamics handbook; use the resulting fuel flow and the supplied combustor total-pressure loss as inputs here.

A practical calculation takes a candidate compressor map point, obtains its work and outlet pressure, imposes combustor outlet conditions, and tests the turbine flow capacity and power balance. Change the candidate until all residuals vanish. For multiple spools, write one power balance per independent shaft. A turbine driving only the core compressor supplies that compressor's work; fan work belongs to the shaft that drives the fan. Stage counts do not multiply the total shaft balance: total turbine power equals total compressor demand plus specified losses and auxiliary loads.

9.3 Turbine flow capacity and the operating lineAE

A choked turbine nozzle throat fixes a corrected-flow capacity. It links turbine inlet pressure and temperature to the mass rate and therefore constrains the compressor operating line. Use a nozzle model only where its assumptions apply, not for a whole blade row with unknown losses.

For fixed effective throat area and gas properties, choked turbine flow makes m˙tT04/p04\dot m_t\sqrt{T_{04}}/p_{04} constant. Once combustor loss and turbine inlet temperature are specified, this constraint and the power balance locate candidate operating points on the compressor map. Stable operation must also remain clear of its surge boundary and within component temperature and speed limits.

Last-minute recall

  • Matching requires one physical flow path and a balanced shaft.
  • Apply map corrections at each component's own inlet total conditions.
  • Compressor and turbine corrected rpm are generally different on one spool.
  • Include fuel, bleed and auxiliary power when they are specified.
  • Combustor pressure loss changes turbine inlet pressure and matching.
  • Choking fixes corrected flow capacity, not physical flow at all inlet conditions.
  • Map compatibility and shaft balance must hold together.

Revise offline: the whole Turbomachinery handbook as one PDF

46 pages · 1.8 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections