Symbols and units

QuantitySymbolSI unit / practical unitConvention
Temperature, environment temperatureT,T0T,T_0KRatios and logarithms use absolute temperature
Pressure, environment pressurep,p0p,p_0Pa / kPaAbsolute unless gauge labelled
Volume, specific volume, molar volumeV,v,vˉV,v,\bar vm³; m³/kg; m³/kmolv=1/ρv=1/\rho
Mass, mass rate, amount, molar massm,m˙,N,Mm,\dot m,N,Mkg; kg/s; kmol; kg/kmolSubscript ff fuel except saturation tables
Internal energy, enthalpyU,H,u,h,hˉU,H,u,h,\bar hJ; J/kg; J/kmolUppercase total, lowercase specific, bar molar
Total energy, speed, elevation, gravityE,C,z,gE,C,z,gJ; m/s; m; m/s²Kinetic term in J/kg is C2/2C^2/2
Heat and workQ,W,qh,wQ,W,q_h,wJ; J/kgHeat into, work out positive
Shaft work, useful workWs,WuW_s,W_uJRates carry a dot
Specific heats and gas constantscp,cv,c,R,Ru,cˉpc_p,c_v,c,R,R_u,\bar c_pJ/(kg K); J/(kmol K) for molar termsγ=cp/cv\gamma=c_p/c_v
Entropy, specific entropy, generationS,s,SgenS,s,S_{\rm gen}J/K; J/(kg K); J/KGeneration is nonnegative
Fractions and qualityyi,Yi,xy_i,Y_i,x1Mole fraction; mass fraction; vapour mass quality
Saturation differenceshfg,sfg,vfgh_{fg},s_{fg},v_{fg}J/kg; J/(kg K); m³/kgSaturated vapour minus liquid
Torque, shaft angle, angular speedτsh,θ,ω\tau_{\rm sh},\theta,\omegaN m; rad; rad/sPositive output direction
Piston/flow area, spring stiffness, displacementA,ks,xsA,k_s,x_sm²; N/m; mxsx_s is spring displacement
Electrical voltage/current, timeVe,Ie,tV_e,I_e,tV; A; sElectrical work input stated as positive magnitude
Polytropic index, heat-capacity ration,γn,\gamma1nn is a path exponent
Compressibility, reduced states, critical stateZ,pr,Tr,pc,Tc,vˉcZ,p_r,T_r,p_c,T_c,\bar v_c1; Pa; K; m³/kmolZcZ_c is model dependent
Virial and van der Waals coefficientsBvir(T),Cvir(T),a,bvdWB_{\rm vir}(T),C_{\rm vir}(T),a,b_{\rm vdW}m³/kmol; (m³/kmol)²; Pa(m³/kmol)²; m³/kmolBvirB_{\rm vir} distinguished from total exergy BB
Thermodynamic potentialsfH,gGf_H,g_GJ/kgHelmholtz and Gibbs specific energies
Response coefficients, sound speedβ,κT,κs,as\beta,\kappa_T,\kappa_s,a_sK⁻¹; Pa⁻¹; Pa⁻¹; m/sVolume expansion; isothermal/isentropic compressibility
Joule–Thomson and Joule coefficientsμJT,μJ\mu_{JT},\mu_JK/Pa; K kg/m³Constant hh and constant uu, respectively
Physical exergiesb,ψ,B,XQ,Xdestb,\psi,B,X_Q,X_{\rm dest}J/kg; J/kg; J; J; JCovolume is bvdWb_{\rm vdW}
Body heat capacitiesCA,CBC_A,C_BJ/KTotal, not per mass
Cycle ratiosr,rc,rp,αD,τp,aBr,r_c,r_p,\alpha_D,\tau_p,a_B1Compression, cutoff, pressure, dual pressure, Brayton temperature factor and exponent
Efficiency, COP, work ratiosη,COP,BWR,WR\eta,\mathrm{COP},\mathrm{BWR},\mathrm{WR}1Fraction unless explicitly percentage
Mean effective pressurepmep_{me}Pa / kPaNet cycle work divided by swept volume
Fuel/air, equivalence, excess-air factorsf,A/F,ϕ,λf,A/F,\phi,\lambdakg/kg; kg/kg; 1; 1f=F/Af=F/A, λ=1/ϕ\lambda=1/\phi
Atomic counts, oxygen demand, air nitrogen ratioaC,aH,aO,aN,aS,νO2,χa_C,a_H,a_O,a_N,a_S,\nu_{O_2},\chi1; kmol/kmol fuel; kmol/kmolχ=3.76\chi=3.76 is the stated dry-air model
Heating values, combustion efficiencyHHV,LHV,ηbHHV,LHV,\eta_bJ/kg fuel; 1Reference water phase matters
Variable-heat gas table functionss∘,prel,vrel,T∗,ϑs^\circ,p_{\rm rel},v_{\rm rel},T_*,\varthetaJ/(kg K); 1; 1; K; KCommon normalisation in ratios
Reaction energy changes and gas amount changeΔHrxn,ΔUrxn,ΔNg\Delta H_{\rm rxn},\Delta U_{\rm rxn},\Delta N_gJ; J; kmolPer stated reaction basis
Phase-rule variablesF,Ccomp,PphF,C_{\rm comp},P_{\rm ph}countsDegrees of freedom, components, phases
Stagnation enthalpy and temperatureht,Tth_t,T_tJ/kg; KTotal conditions; environment uses subscript 0
Melting temperature, fusion enthalpy, phase heats, furnace efficiencyTm,hfus,cp,s,cp,ℓ,ηfurnaceT_m,h_{\rm fus},c_{p,s},c_{p,\ell},\eta_{\rm furnace}K; J/kg; J/(kg K); 1Solid and liquid at the stated pressure
General potential and differential coefficientsF,AX,AY\mathcal F,A_X,A_YPotential units; [F]/[X][\mathcal F]/[X]; [F]/[Y][\mathcal F]/[Y]Local independent coordinates X,YX,Y
Elastic length and tensile force; liquid depthL,FL,zℓL,F_L,z_\ellm; N; mStretch work input positive; liquid depth above vessel base

Subscripts 1, 2, … denote locally numbered states; a,sa,s on a device outlet mean actual and isentropic. Subscripts f,gf,g mean saturated liquid/vapour in Chapter 5 and fuel/product gas in Chapter 8. Subscript ii denotes a component or inlet as stated; oo denotes outlet. Subscripts H,LH,L mean hot/cold, bb boundary, and st\rm st stoichiometric. Helpers X,Y,ZX,Y,Z in derivative rules and yy in property interpolation are local dummy variables.