Chapter 4

Second law and entropy

The first law checks energy conservation. The second law checks whether the proposed transfers and state changes can occur. Entropy change is a state difference; entropy generation depends on the process and chosen boundary.

4.1 Heat engines and reversed cycles

Past papers · ME 2020–2026 (10 papers): 3 questions, 4 marks

Kelvin–Planck: a cyclic device cannot have as its sole effect the conversion of heat from one reservoir entirely into work. Clausius: a cyclic device cannot have as its sole effect heat transfer from a colder body to a hotter body. A perpetual-motion machine of the first kind violates energy conservation; one of the second kind violates the second law.

For two heat engines in series, with all heat rejected by the first supplied to the second and no other heat paths, ηoverall=1−(1−η1)(1−η2)\eta_{\rm overall}=1-(1-\eta_1)(1-\eta_2). If a heat engine drives a refrigerator, use QL,R=COPRWengineQ_{L,R}=\mathrm{COP}_R W_{\rm engine}; balance the heat received by each reservoir separately.

A Carnot cycle uses two reversible isotherms and two reversible adiabats. Its working substance need not be an ideal gas. COP can exceed one because the useful effect includes heat moved from another source.

4.2 Entropy balances and Clausius inequality

Past papers · ME 2020–2026 (10 papers): 4 questions, 7 marks

Include the thermal contact region if you want its irreversibility counted. For a reservoir at constant TRT_R, ΔSR=−Q/TR\Delta S_R=-Q/T_R when it supplies heat QQ to the system. For an isolated combined system, ΔStotal=Sgen≥0\Delta S_{\rm total}=S_{\rm gen}\ge0. Work transfers no entropy. For a conducting slab, first find its boundary temperatures using the Heat Transfer handbook, then apply this entropy balance.

4.3 Entropy changes from properties

Past papers · ME 2020–2026 (10 papers): 2 questions, 3 marks

For a reversible equilibrium phase change, sfg=hfg/Tsats_{fg}=h_{fg}/T_{\rm sat}. For internally reversible heat transfer, qh=∫T dsq_h=\int T\,ds; area under a TT–ss path is heat only with that condition. An adiabatic irreversible closed system has increasing entropy.

4.4 Mixing and finite thermal bodiesME

For a body of constant total heat capacity CBC_B heated from TiT_i to TfT_f solely by a constant-temperature reservoir at TRT_R, the combined entropy generation is Sgen=CBln⁡(Tf/Ti)−CB(Tf−Ti)/TRS_{\rm gen}=C_B\ln(T_f/T_i)-C_B(T_f-T_i)/T_R. The same signed expression covers cooling to a colder reservoir.

Removing a partition between samples of the same gas at identical T,pT,p does not create mixing entropy. For gases initially at different temperatures or pressures, the simple −Ru∑Niln⁡yi-R_u\sum N_i\ln y_i expression alone is insufficient.

Last-minute recall

  • Reservoir temperature ratios use kelvin.
  • A reversible engine gives the maximum two-reservoir efficiency.
  • Entropy can decrease in a system that rejects heat.
  • Entropy generation cannot be negative.
  • Entropy carried by heat uses the boundary temperature.
  • Irreversible paths still use property equations for Δs\Delta s.
  • Direct thermal equilibration uses an energy balance before an entropy balance.

Revise offline: the whole Thermodynamics handbook as one PDF

46 pages · 2.0 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections