Gas power cycles
Use the air-standard model to replace combustion by heat addition and exhaust by heat rejection. Constant- formulas additionally require constant specific heats. Number states along the actual cycle before forming temperature ratios.
7.1 Ideal Brayton cycle
Past papers · AE 2020–2026 (7 papers): 2 questions, 2 marks
States are: 1 compressor inlet, 2 compressor outlet, 3 turbine inlet, 4 turbine outlet. Processes 1–2 and 3–4 are isentropic; 2–3 and 4–1 are constant-pressure heat addition and rejection. The simple closed air-standard cycle has the same mass through every process.
Original temperature–entropy diagram of an ideal constant-specific-heat Brayton cycle.
7.2 Pressure ratio for maximum Brayton work
7.3 Brayton cycle with component losses
Past papers · ME 2020–2026 (10 papers): 1 question, 2 marks
For equal pressure ratios, fixed efficiencies and fixed , differentiating net work gives , provided it lies in a feasible operating interval. At unit efficiencies the ideal optimum returns. For a real open combustor, account for added fuel mass and different gas properties using the energy balance; do not silently use this equal-mass model.
7.4 Otto cycle
Past papers · ME 2020–2026 (10 papers): 2 questions, 3 marks
The cold-air-standard Otto cycle has isentropic compression 1–2, constant-volume heat addition 2–3, isentropic expansion 3–4, and constant-volume rejection 4–1.
Compression ratio is total maximum volume divided by clearance volume: add swept and clearance volumes before dividing. Brake/indicated power and mechanical efficiency: see the Thermal Applications handbook.
With fixed minimum and maximum , maximum work occurs at and equals . This is an optimisation with fixed temperature limits, not fixed heat input.
7.5 Diesel cycle
Past papers · ME 2020–2026 (10 papers): 2 questions, 3 marks
Heat addition 2–3 is at constant pressure; heat rejection 4–1 is at constant volume. Compression 1–2 and expansion 3–4 are isentropic.
At fixed and , increasing cutoff lowers efficiency. The limit gives the Otto efficiency, although heat and work both approach zero if other parameters remain fixed. Never infer the efficiency ranking of actual petrol and diesel engines from an equal-compression-ratio ideal-cycle comparison.
7.6 Dual cycle and cycle comparisons
Use five states: 1–2 isentropic compression, 2–3 constant-volume heat addition, 3–4 constant-pressure heat addition, 4–5 isentropic expansion, and 5–1 constant-volume rejection.
For the same initial state, compression ratio, specific heats and heat input, when both heat-addition portions are nonzero. Do not use that ranking under different fixed constraints; calculate each set of state temperatures.
7.7 Stirling and Ericsson cycle limits
Past papers · AE 2020–2026 (7 papers): 1 question, 1 mark · ME 2020–2026 (10 papers): 1 question, 1 mark
These ideal reference cycles have two isothermal processes. Stirling joins them by constant-volume processes; Ericsson joins them by constant-pressure processes. With perfect internal recovery of heat on the joining processes, all external heat exchange is isothermal.
Last-minute recall
- Brayton heat transfer uses ; Otto heat transfer uses .
- Maximum Brayton work is not maximum Brayton efficiency.
- Apply compressor and turbine efficiencies in opposite directions.
- Keep actual compressor and turbine pressure ratios separate if losses are given.
- Diesel cutoff is a volume ratio during constant-pressure heat addition.
- Dual-cycle state numbering has five states.
- Compare efficiencies only after checking which constraints are fixed.
- Do not use ideal cycle heat input as an actual fuel consumption without a combustion balance.