Vapour power cycles
Begin with a mass-flow diagram and a table of enthalpies. A simple Rankine loop has one mass flow everywhere; extraction cycles do not. Steam properties come from the supplied tables, not ideal-gas equations.
1.1 Simple Rankine cycle
Use 1 at condenser exit, 2 at pump exit, 3 at boiler exit and 4 at turbine exit. The ideal pump and turbine are isentropic; boiler and condenser operate at constant pressure. State 1 is saturated liquid; state 3 may be saturated or superheated vapour.
For a superheated turbine outlet, use in the superheat table. A computed quality above one means that the two-phase formula was used outside its domain. Wet-steam compression makes a vapour Carnot cycle impractical; Rankine condenses fully before pumping.
Rankine component loop with the state numbering used in Section 1.1.
1.2 Actual turbine and pump
Past papers · ME 2020–2026 (10 papers): 1 question, 2 marks
Keep the same inlet and outlet pressures when comparing actual and isentropic devices. For an adiabatic irreversible device, entropy increases; adiabatic alone does not mean isentropic.
1.3 Plant performance and operating trends
Past papers · ME 2020–2026 (10 papers): 2 questions, 3 marks
Thermal efficiency uses net cycle work. Boiler efficiency, generator efficiency and auxiliary losses are separate quantities and must be included only when the question supplies them.
| Change, with other stated limits fixed | Usual ideal Rankine consequence | Constraint |
|---|---|---|
| Lower condenser pressure, fixed turbine inlet | More turbine work and higher efficiency | Wetter exhaust; cooling-water temperature and air leakage limit vacuum |
| Higher boiler pressure, fixed inlet temperature and condenser pressure | Higher mean heat-addition temperature; efficiency generally rises | Exhaust quality generally falls; net-work trend is not universal |
| More superheat, fixed boiler and condenser pressures | Higher work, efficiency and exhaust quality | Material temperature limit |
| Reheat at an intermediate pressure | Higher exhaust quality and usually more work | Efficiency requires calculation |
| Regenerative feed heating | Raises average external heat-addition temperature | Less steam completes the turbine expansion |
1.4 Reheat Rankine cycle
Past papers · ME 2020–2026 (10 papers): 3 questions, 6 marks
Number the states 1 condenser exit, 2 pump exit, 3 high-pressure turbine inlet, 4 high-pressure turbine exit, 5 reheater exit and 6 low-pressure turbine exit. Reheat adds heat at an intermediate pressure before the second expansion.
1.5 One open feedwater heater
Past papers · ME 2020–2026 (10 papers): 2 questions, 4 marks
An open heater mixes extracted steam with feedwater at the same pressure. Use a basis of 1 kg entering the boiler. Let fraction be extracted at state ; the remaining expands to turbine exhaust . Condenser liquid at 1 is pumped to heater inlet 2; the heater discharges at 3 and a second pump delivers state 4 to the boiler; turbine inlet is 5.
1.6 Closed heaters and drain routing
A closed heater transfers heat through a wall; the feedwater and bleed steam need not have equal pressures. Always trace the drains: pumping them forward and throttling them backward give different downstream mass flows.
For an ideal condensing closed heater without a drain cooler, the drains are saturated liquid at bleed pressure and the feedwater outlet approaches that saturation temperature. Feedwater enthalpy must still be evaluated at its own pressure. The terminal temperature difference is the bleed saturation temperature minus feedwater outlet temperature; zero is an idealisation.
1.7 Several extraction stages
Label every stream as a fraction of the original boiler flow before writing an energy balance. A later extraction fraction is not automatically a fraction of the smaller flow reaching that stage.
Solve heater mass and energy equations using the actual drain routing. Then sum mass-weighted boiler and reheater inputs and condenser rejection. Check that heat input minus rejection equals net work per kg of boiler flow. Regeneration recovers energy internally; bleed heat is not external boiler heat input.
Last-minute recall
- Draw and number the states before reading enthalpies.
- Turbine work is an enthalpy drop; pump work is an enthalpy rise.
- Use liquid specific volume for , with compatible pressure units.
- Quality exists only inside the saturation dome.
- Reheat primarily controls moisture; calculate its efficiency effect.
- Open heaters mix at one pressure; closed heaters separate the fluids.
- Multiply every stage work and heat transfer by its actual flow fraction.
- SSC uses net kJ/kg; the conversion factor is 3600 kJ/kWh.