Chapter 1

Vapour power cycles

Begin with a mass-flow diagram and a table of enthalpies. A simple Rankine loop has one mass flow everywhere; extraction cycles do not. Steam properties come from the supplied tables, not ideal-gas equations.

1.1 Simple Rankine cycle

Use 1 at condenser exit, 2 at pump exit, 3 at boiler exit and 4 at turbine exit. The ideal pump and turbine are isentropic; boiler and condenser operate at constant pressure. State 1 is saturated liquid; state 3 may be saturated or superheated vapour.

For a superheated turbine outlet, use (p4,s3)(p_4,s_3) in the superheat table. A computed quality above one means that the two-phase formula was used outside its domain. Wet-steam compression makes a vapour Carnot cycle impractical; Rankine condenses fully before pumping.

Rankine component loop with the state numbering used in Section 1.1.Rankine component loop with the state numbering used in Section 1.1.

1.2 Actual turbine and pump

Past papers · ME 2020–2026 (10 papers): 1 question, 2 marks

Keep the same inlet and outlet pressures when comparing actual and isentropic devices. For an adiabatic irreversible device, entropy increases; adiabatic alone does not mean isentropic.

1.3 Plant performance and operating trends

Past papers · ME 2020–2026 (10 papers): 2 questions, 3 marks

Thermal efficiency uses net cycle work. Boiler efficiency, generator efficiency and auxiliary losses are separate quantities and must be included only when the question supplies them.

Change, with other stated limits fixedUsual ideal Rankine consequenceConstraint
Lower condenser pressure, fixed turbine inletMore turbine work and higher efficiencyWetter exhaust; cooling-water temperature and air leakage limit vacuum
Higher boiler pressure, fixed inlet temperature and condenser pressureHigher mean heat-addition temperature; efficiency generally risesExhaust quality generally falls; net-work trend is not universal
More superheat, fixed boiler and condenser pressuresHigher work, efficiency and exhaust qualityMaterial temperature limit
Reheat at an intermediate pressureHigher exhaust quality and usually more workEfficiency requires calculation
Regenerative feed heatingRaises average external heat-addition temperatureLess steam completes the turbine expansion

1.4 Reheat Rankine cycle

Past papers · ME 2020–2026 (10 papers): 3 questions, 6 marks

Number the states 1 condenser exit, 2 pump exit, 3 high-pressure turbine inlet, 4 high-pressure turbine exit, 5 reheater exit and 6 low-pressure turbine exit. Reheat adds heat at an intermediate pressure before the second expansion.

1.5 One open feedwater heater

Past papers · ME 2020–2026 (10 papers): 2 questions, 4 marks

An open heater mixes extracted steam with feedwater at the same pressure. Use a basis of 1 kg entering the boiler. Let fraction yy be extracted at state bb; the remaining 1−y1-y expands to turbine exhaust ee. Condenser liquid at 1 is pumped to heater inlet 2; the heater discharges at 3 and a second pump delivers state 4 to the boiler; turbine inlet is 5.

1.6 Closed heaters and drain routing

A closed heater transfers heat through a wall; the feedwater and bleed steam need not have equal pressures. Always trace the drains: pumping them forward and throttling them backward give different downstream mass flows.

For an ideal condensing closed heater without a drain cooler, the drains are saturated liquid at bleed pressure and the feedwater outlet approaches that saturation temperature. Feedwater enthalpy must still be evaluated at its own pressure. The terminal temperature difference is the bleed saturation temperature minus feedwater outlet temperature; zero is an idealisation.

1.7 Several extraction stages

Label every stream as a fraction of the original boiler flow before writing an energy balance. A later extraction fraction is not automatically a fraction of the smaller flow reaching that stage.

Solve heater mass and energy equations using the actual drain routing. Then sum mass-weighted boiler and reheater inputs and condenser rejection. Check that heat input minus rejection equals net work per kg of boiler flow. Regeneration recovers energy internally; bleed heat is not external boiler heat input.

Last-minute recall

  • Draw and number the states before reading enthalpies.
  • Turbine work is an enthalpy drop; pump work is an enthalpy rise.
  • Use liquid specific volume for vΔpv\Delta p, with compatible pressure units.
  • Quality exists only inside the saturation dome.
  • Reheat primarily controls moisture; calculate its efficiency effect.
  • Open heaters mix at one pressure; closed heaters separate the fluids.
  • Multiply every stage work and heat transfer by its actual flow fraction.
  • SSC uses net kJ/kg; the conversion factor is 3600 kJ/kWh.

Revise offline: the whole Thermal Applications: Power Cycles, IC Engines, Refrigeration and Air-Conditioning handbook as one PDF

39 pages · 1.6 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections