| Absolute / Celsius temperature | T,TC | K / °C | Kelvin in ratios, Celsius in the stated moist-air enthalpy model |
| State / reservoir temperatures | Ti,TL,TH,TG,T0,Tmin,Tmax,Tm | K | State, cold, hot, generator, sink, limits and entropy-weighted mean |
| Dry bulb, wet bulb, dew point, adiabatic saturation | Tdb,Twb,Tdp,Tas | K or °C as labelled | Suffix C explicitly selects Celsius |
| Pressure and partial pressures | p,pH,pL,pa,pv,pws | kPa | Absolute; dry-air, vapour and saturation partial pressures |
| Total / specific volume | V,v | m³ / m³/kg | For moist air, kg means kg dry air |
| Enthalpy / entropy | h,s | kJ/kg / kJ/(kg K) | Moist-air h is per kg dry air; vapour and liquid h are per kg water |
| Saturated-liquid values and phase increments | hf,sf,hfg,sfg | kJ/kg; kJ/(kg K) | fg denotes saturated vapour minus saturated liquid |
| Vapour quality | x,xflash | 1 | Only for two-phase liquid–vapour states |
| Heat / work magnitudes | Q,W,qin,qout,qL,qH,wt,wp,wc,wnet | kJ / kJ/kg | Capital Q,W are total transfers; lowercase quantities are specific; net work is output for power cycles |
| Heat / power rates | Q˙,W˙ | kW | Dot indicates per second; air-process Q positive into air unless cooling magnitude is specified |
| Mass / mass rate | m,m˙ | kg / kg/s | a dry air, v vapour, r refrigerant, w water, cond condensate, cw cooling water |
| Bleed and stage-flow fractions | y,yi,fi,gk | 1 | Referenced to boiler mass flow; g_k denotes pump-stage fraction |
| Heater enthalpies | hb,hd,hi,ho,hd,p,hmix | kJ/kg | Bleed, drain, inlet/outlet feed, pumped drain and mixed state; local numbering stated |
| Specific heats / gas constants | cp,cv,cp,ℓ,cp,ma,cp,cw,R,Ra | kJ/(kg K) | ma per kg dry air; Ra=0.287 in kPa·m³/(kg K) |
| Heat-capacity ratio | γ | 1 | cp/cv; cold-air cycle formulas keep it constant |
| Thermal / component efficiencies | ηth,ηO,ηD,ηdual,ηt,ηp,ηc | 1 | Fractions, with percentage explicitly marked |
| Volumetric, mechanical, motor, second-law efficiencies | ηv,ηm,ηmotor,ηII,R | 1 | Each boundary is defined in its topic |
| Steam and heat rates | SSC,HR | kg/kWh; kJ/kWh | Net cycle output basis |
| Back-work / work ratios | BWR,WR | 1 | Pump input/turbine output; net output/turbine output |
| Engine geometry | D,Ls,Vs,Vc,Ccl | m; m; m³; m³; 1 | Bore, stroke, swept and clearance volume, clearance/swept ratio |
| Engine / gas-cycle ratios | r,rc,αD,rp | 1 | Compression volume, cutoff volume, CV heat-addition pressure rise, gas-cycle pressure ratio |
| Otto / Brayton factors | aO,aB,θB | 1 | rγ−1; (γ−1)/γ; rpaB |
| Mean effective pressure | pme | kPa | Net work divided by swept volume |
| Constant-volume heat contribution | qcv | kJ/kg | Used to split dual-cycle heat addition |
| Coefficients of performance | COPR,COPHP,COPabs | 1 | Refrigeration, heat pump, heat-driven absorption |
| Refrigeration capacity unit | TR | 3.517 kW approximately | Thermal capacity, not a mass |
| Suction / swept volume rate | V˙1,V˙swept,V˙ | m³/s | Evaluate suction volume at compressor inlet |
| Volumetric refrigeration effect | qL,vol | kJ/m³ | Specific cooling divided by suction specific volume |
| Subcooling temperature decrease | ΔTsub | K | Positive decrease below the condenser saturation temperature |
| Humidity ratios | ω,ωs | kg water/kg dry air | s denotes saturation at the stated temperature; room-state subscript s means supply and is explicitly local |
| Relative humidity / saturation degree / water mass fraction | ϕ,μsat,Yv | 1 | Distinct quantities; phi means relative humidity here, equivalence ratio in the Thermodynamics handbook's combustion topic |
| Moist-air density | ρ | kg moist air/m³ | Total mass per volume, unlike the dry-air specific-volume basis |
| Dry-air, vapour and liquid enthalpies | ha,hv,hℓ,hw | kJ/kg respective component | hw is the injected water/steam enthalpy |
| Coil and evaporative factors | BF,CF,εevap | 1 | Bypass fraction, contact factor, direct evaporative effectiveness |
| Apparatus dew point | ADP | Saturated state | Effective coil surface state at the specified pressure |
| Room-load variables | Q˙s,Q˙ℓ,SHF,ωˉ,hfg,ref | kW; kW; 1; kg/kg dry air; kJ/kg water | Sensible and latent loads, sensible heat factor, representative humidity and specified latent heat |