Symbols and units

QuantitySymbolUnitNote
Absolute / Celsius temperatureT,TCT,T_CK / °CKelvin in ratios, Celsius in the stated moist-air enthalpy model
State / reservoir temperaturesTi,TL,TH,TG,T0,Tmin⁡,Tmax⁡,TmT_i,T_L,T_H,T_G,T_0,T_{\min},T_{\max},T_mKState, cold, hot, generator, sink, limits and entropy-weighted mean
Dry bulb, wet bulb, dew point, adiabatic saturationTdb,Twb,Tdp,TasT_{\rm db},T_{\rm wb},T_{\rm dp},T_{\rm as}K or °C as labelledSuffix C explicitly selects Celsius
Pressure and partial pressuresp,pH,pL,pa,pv,pwsp,p_H,p_L,p_a,p_v,p_{ws}kPaAbsolute; dry-air, vapour and saturation partial pressures
Total / specific volumeV,vV,vm³ / m³/kgFor moist air, kg means kg dry air
Enthalpy / entropyh,sh,skJ/kg / kJ/(kg K)Moist-air h is per kg dry air; vapour and liquid h are per kg water
Saturated-liquid values and phase incrementshf,sf,hfg,sfgh_f,s_f,h_{fg},s_{fg}kJ/kg; kJ/(kg K)fg denotes saturated vapour minus saturated liquid
Vapour qualityx,xflashx,x_{\rm flash}1Only for two-phase liquid–vapour states
Heat / work magnitudesQ,W,qin,qout,qL,qH,wt,wp,wc,wnetQ,W,q_{\rm in},q_{\rm out},q_L,q_H,w_t,w_p,w_c,w_{\rm net}kJ / kJ/kgCapital Q,W are total transfers; lowercase quantities are specific; net work is output for power cycles
Heat / power ratesQ˙,W˙\dot Q,\dot WkWDot indicates per second; air-process Q positive into air unless cooling magnitude is specified
Mass / mass ratem,m˙m,\dot mkg / kg/sa dry air, v vapour, r refrigerant, w water, cond condensate, cw cooling water
Bleed and stage-flow fractionsy,yi,fi,gky,y_i,f_i,g_k1Referenced to boiler mass flow; g_k denotes pump-stage fraction
Heater enthalpieshb,hd,hi,ho,hd,p,hmixh_b,h_d,h_i,h_o,h_{d,p},h_{\rm mix}kJ/kgBleed, drain, inlet/outlet feed, pumped drain and mixed state; local numbering stated
Specific heats / gas constantscp,cv,cp,ℓ,cp,ma,cp,cw,R,Rac_p,c_v,c_{p,\ell},c_{p,\rm ma},c_{p,\rm cw},R,R_akJ/(kg K)ma per kg dry air; Ra=0.287R_a=0.287 in kPa·m³/(kg K)
Heat-capacity ratioγ\gamma1cp/cvc_p/c_v; cold-air cycle formulas keep it constant
Thermal / component efficienciesηth,ηO,ηD,ηdual,ηt,ηp,ηc\eta_{\rm th},\eta_O,\eta_D,\eta_{\rm dual},\eta_t,\eta_p,\eta_c1Fractions, with percentage explicitly marked
Volumetric, mechanical, motor, second-law efficienciesηv,ηm,ηmotor,ηII,R\eta_v,\eta_m,\eta_{\rm motor},\eta_{II,R}1Each boundary is defined in its topic
Steam and heat ratesSSC,HR\mathrm{SSC},\mathrm{HR}kg/kWh; kJ/kWhNet cycle output basis
Back-work / work ratiosBWR,WR\mathrm{BWR},\mathrm{WR}1Pump input/turbine output; net output/turbine output
Engine geometryD,Ls,Vs,Vc,CclD,L_s,V_s,V_c,C_{\rm cl}m; m; m³; m³; 1Bore, stroke, swept and clearance volume, clearance/swept ratio
Engine / gas-cycle ratiosr,rc,αD,rpr,r_c,\alpha_D,r_p1Compression volume, cutoff volume, CV heat-addition pressure rise, gas-cycle pressure ratio
Otto / Brayton factorsaO,aB,θBa_O,a_B,\theta_B1rγ−1r^{\gamma-1}; (γ−1)/γ(\gamma-1)/\gamma; rpaBr_p^{a_B}
Mean effective pressurepmep_{me}kPaNet work divided by swept volume
Constant-volume heat contributionqcvq_{\rm cv}kJ/kgUsed to split dual-cycle heat addition
Coefficients of performanceCOPR,COPHP,COPabs\mathrm{COP}_R,\mathrm{COP}_{HP},\mathrm{COP}_{\rm abs}1Refrigeration, heat pump, heat-driven absorption
Refrigeration capacity unitTR\mathrm{TR}3.517 kW approximatelyThermal capacity, not a mass
Suction / swept volume rateV˙1,V˙swept,V˙\dot V_1,\dot V_{\rm swept},\dot Vm³/sEvaluate suction volume at compressor inlet
Volumetric refrigeration effectqL,volq_{L,\rm vol}kJ/m³Specific cooling divided by suction specific volume
Subcooling temperature decreaseΔTsub\Delta T_{\rm sub}KPositive decrease below the condenser saturation temperature
Humidity ratiosω,ωs\omega,\omega_skg water/kg dry airs denotes saturation at the stated temperature; room-state subscript s means supply and is explicitly local
Relative humidity / saturation degree / water mass fractionϕ,μsat,Yv\phi,\mu_{\rm sat},Y_v1Distinct quantities; phi means relative humidity here, equivalence ratio in the Thermodynamics handbook's combustion topic
Moist-air densityρ\rhokg moist air/m³Total mass per volume, unlike the dry-air specific-volume basis
Dry-air, vapour and liquid enthalpiesha,hv,hℓ,hwh_a,h_v,h_\ell,h_wkJ/kg respective componenthwh_w is the injected water/steam enthalpy
Coil and evaporative factorsBF,CF,εevap\mathrm{BF},\mathrm{CF},\varepsilon_{\rm evap}1Bypass fraction, contact factor, direct evaporative effectiveness
Apparatus dew pointADPSaturated stateEffective coil surface state at the specified pressure
Room-load variablesQ˙s,Q˙ℓ,SHF,ωˉ,hfg,ref\dot Q_s,\dot Q_\ell,\mathrm{SHF},\bar\omega,h_{fg,\rm ref}kW; kW; 1; kg/kg dry air; kJ/kg waterSensible and latent loads, sensible heat factor, representative humidity and specified latent heat

Revise offline: the whole Thermal Applications: Power Cycles, IC Engines, Refrigeration and Air-Conditioning handbook as one PDF