Chapter 5

Direct stiffness matrix method

Choose global displacement coordinates, form member matrices, transform and assemble them, then impose restraints. The same method handles trusses, beams, frames, springs and support settlements. Reactions follow from the restrained rows after solving the free coordinates.

5.1 Assembly and prescribed displacements

Each column of a stiffness matrix contains the nodal actions required by a unit displacement at that coordinate while all other coordinates are held zero. A restrained stable elastic system has symmetric positive-definite Kff\boldsymbol K_{ff}. The unreduced matrix has rigid-body zero modes. A remaining zero mode after restraints usually indicates a mechanism or omitted restraint. Use a linear solve, not an explicitly computed inverse.

5.2 Bar and plane-truss element

Past papers · CE 2020–2026 (14 papers): 1 question, 2 marks

A plane truss has no joint rotational degrees of freedom. One element has only one deformational mode; its global matrix has rank one. For two equal bars meeting symmetrically at angles ±β\pm\beta with fixed remote ends, the joint matrix is (EA/L)diag⁡(2c2,2s2)(EA/L)\operatorname{diag}(2c^2,2s^2); off-diagonal terms cancel. At 45∘45^\circ, both diagonal terms equal EA/LEA/L.

5.3 Beam element and consistent nodal loads

Past papers · CE 2020–2026 (14 papers): 1 question, 2 marks

5.4 Plane-frame transformation

For frame analysis: number the coordinates; compute local matrices and load vectors; transform; assemble; impose prescribed movements; solve; recover local displacements and end actions; finally check equilibrium. Do not replace a member by a beam-only element if its axial stiffness is needed to restrain the frame.

5.5 Releases and static condensation

Setting an end rotation to zero creates a fixed rotational restraint, not a hinge. Deleting a stiffness row and column without condensation can silently introduce the wrong model. A translational spring to ground adds its stiffness to the relevant diagonal; a spring between two coordinates adds ks[1−1−11]k_s\begin{bmatrix}1&-1\\-1&1\end{bmatrix} to their block.

Last-minute recall

  • Assemble in one coordinate system.
  • A truss joint has two translations; a frame joint also has a rotation.
  • Apply prescribed settlements through the partitioned right-hand side.
  • The restrained stiffness matrix must have no unintended zero modes.
  • Equivalent member loads are opposite to locked-end reactions.
  • Recover end actions as stiffness times displacement minus equivalent loads.
  • A release requires condensation, not a zero prescribed rotation.
  • Check reactions using the full assembled system.

Revise offline: the whole Structural Analysis handbook as one PDF

53 pages · 2.3 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections