Symbols and units
The table fixes the handbook conventions. A symbol reused for an unrelated local role is identified in its section. is the imaginary unit; means complex conjugation, while an infix means convolution.
| Quantity | Symbol | Unit | Note |
|---|---|---|---|
| Time and integer indices | ; | s; integers | may also be a time constant or sampling offset, defined locally. |
| Durations and sampling interval | s | Window, period, sample spacing and hold duration; is not temperature here. | |
| Ordinary and angular frequency | ; | Hz; rad/s | means sample angular rate in Chapter 6 and analogue stopband edge in Section 9.5. |
| Digital angular frequency | rad/sample | Periodic modulo ; is a transition width; in DTFT integrals also has rad/sample units. | |
| Bandwidth and analogue design edges | ; | Hz; rad/s | ; is the prewarped analogue frequency; CT spectral integration variable is rad/s. |
| Signals and parity parts | Signal units | denotes the physical input unit; subscript denotes reversal where used. | |
| CT and DT impulse | s; 1 | CT impulse has unit area; DT impulse has unit sample height. | |
| Step, ramp and sign | 1; s; 1 | Unit ramp ; elsewhere denotes residues. | |
| Shape functions | 1 | Dimensionless arguments; . | |
| Impulse and step responses | CT : ; DT and : | Responses to unit-area impulse or unit-height step; subscripts identify inverse, analogue, impulse invariant. | |
| Transforms | ; | CT: ·s; DT: | is unilateral; is the DFT, also in . |
| Transfer and frequency responses | Filter specifications use dimensionless gain; is a normalised prototype. | ||
| Signal energy and mean-square power | CT : ·s; DT and : | Divide voltage measures by resistance to obtain physical energy or power. | |
| Signal gains and pulse heights | As specified; dimensionless for duty ratio | also denotes CT direct gain in Section 2.3; denotes dB attenuation only in Kaiser design. | |
| Scaling, bases and coefficients | Locally defined | CT decay rates: s; DT exponential bases and time scales: 1; shifts: s; equation coefficients balance units. | |
| Phase and delays | ; | rad; CT s, DT samples | Unwrap phase before differentiation; positive time delay gives negative phase slope. |
| Transform variables, poles and zeros | ; | CT s; DT 1 | is complex frequency; is dimensionless. Subscripted poles/zeros use their system's domain. |
| Fourier coefficients | is DC in trigonometric synthesis; belongs to the second signal. | ||
| Periods, lengths and orders | count | for FIR order; is prototype order or transform length according to section. | |
| DFT factors and subtransforms | 1; ; ; operator | are even/odd-sample DFTs, not energy. | |
| RMS and averages | Last quantity is the rectified average. Form/crest factors are dimensionless. | ||
| Design deviations and losses | ; | 1; dB | uses symmetric ripple; uses unity maximum. is Chebyshev ripple factor. |
| FIR centre, windows and Bessel function | samples; 1; 1; 1 | ; sets Kaiser taper; is modified Bessel order zero. | |
| Real centred FIR factors | even for symmetric FIR; odd for antisymmetric FIR. | ||
| Prototype variables and residues | 1; 1; 1; rad; | normalised frequency; Chebyshev polynomial; simple-pole residues. | |
| Sampling trains and hold | s; s; ; ; 1; 1; s | natural pulse train; hold pulse; its CTFT. | |
| Energy fraction, impulse jump and roots | 1; ; as defined | ; signal jump; in impulse substitution differs from step response. | |
| Inner product and norms | Per definition | CT inner products include seconds; the convolution bound yields output units. |