Chapter 9

Springs

Springs store energy and control force–displacement behaviour. Wire stress, deflection, available travel and fatigue life must all be checked. Distinguish wire torsion in a compression spring from wire bending in a helical torsion spring.

9.1 Close-coiled compression spring

Past papers · ME 2020–2026 (10 papers): 2 questions, 2 marks

Idealised end formActive coil countSolid-height model
PlainNa≃NtN_a\simeq N_tAllow for unground end geometry; often (Nt+1)d(N_t+1)d
Plain and groundNa≃Nt−1N_a\simeq N_t-1NtdN_td
Squared/closedNa≃Nt−2N_a\simeq N_t-2Often (Nt+1)d(N_t+1)d if unground
Squared and groundNa≃Nt−2N_a\simeq N_t-2NtdN_td

The ideal stress sketches distinguish three effects: torsional shear varies linearly across a wire diameter and changes sign at its centre; the elementary direct-shear approximation adds a constant offset; wire curvature further raises the inner-edge peak and makes the distribution nonlinear. Use the no-curvature sum when the question explicitly asks for direct plus torsional shear, and Wahl's expression when curvature is included.

Original schematic stress profiles separate torsion, direct shear and curvature; the third curve is qualitative.Original schematic stress profiles separate torsion, direct shear and curvature; the third curve is qualitative.

These are ideal end-geometry counting conventions; given active coils or a supplied solid height take precedence. Free length must accommodate solid height, maximum working deflection and the specified clash allowance. A long slender spring also needs a buckling check; axial resonance/surge belongs to vibration analysis.

For a fluctuating load, use Fm=(Fmax⁡+Fmin⁡)/2F_m=(F_{\max}+F_{\min})/2 and Fa=(Fmax⁡−Fmin⁡)/2F_a=(F_{\max}-F_{\min})/2, calculate corrected mean/amplitude shear stresses as prescribed, and apply a shear fatigue relation with shear endurance/yield/ultimate strengths. Do not insert shear stress into a normal-stress fatigue diagram without a justified conversion.

9.2 Spring combinations and torsion springs

Past papers · ME 2020–2026 (10 papers): 1 question, 2 marks

For a close-coiled extension spring with initial tension F0F_0, the post-opening relation is F=F0+kδF=F_0+k\delta, with the same ideal coil rate as a compression spring. End hooks require separate bending and stress-concentration checks; the coil formula alone does not size a hook.

9.3 Leaf springs

Leaf springs store bending energy. A rectangular constant-width stack and a graduated stack do not have the same rate even with the same root section. State whether “length” means full eye-to-eye span or half-span.

The semi-elliptic formula follows by taking each half as a graduated cantilever of length L/2L/2 with end load W/2W/2. A stack of equally long rectangular leaves instead has central deflection WL3/(4ENlbltl3)WL^3/(4EN_lb_lt_l^3). Extra full-length leaves in a graduated pack share load by equal deflection, not simply by leaf count. Nipping gives initial curvature differences and prestress to improve stress sharing; include it only with the supplied assembly geometry. The distinct graduated and full-length compliances are documented in IIT Madras, multi-leaf springs.

Last-minute recall

  • Use mean coil diameter, not outside diameter.
  • Compression-spring wire mainly twists; torsion-spring wire mainly bends.
  • Wahl’s factor already includes direct shear.
  • Active coils determine rate; total coils help determine solid height.
  • Doubling d,D,Nad,D,N_a together leaves compression-spring rate unchanged.
  • Series spring rates combine reciprocally.
  • A leaf-spring formula is meaningless without its span convention.
  • Graduated and full-length leaves have different compliances.

Revise offline: the whole Machine Design handbook as one PDF

43 pages · 1.7 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections