Chapter 8

River training structures

River training guides flow, protects banks and manages sediment movement. The appropriate structure depends on whether the objective concerns flood conveyance, bank erosion, low-water navigation or stability of a crossing.

8.1 Objectives and structure roles

Objective or structureFunctionLimitation to remember
High-water trainingConfine or guide floodsEmbankments can raise flood level and transfer risk
Low-water trainingConcentrate low flow to maintain useful depthNavigation improvement is not flood storage
Mean-water trainingManage channel alignment and sediment passageConsider long-term erosion and deposition
Guide bank or guide bundLead flow through a bridge or barrage openingProtect both alignment and exposed noses
Marginal embankment or leveeExclude floods from protected landNeeds adequate crest level and erosion protection
Revetment or pitchingArmour an eroding bank slopeRequires a filter and toe support
Launching apronFlexible bed protection settles into a developing scour slopeNot a rigid impervious seepage floor
Cutoff channelShorten a bend and change alignmentIncreased slope may cause bed adjustment

A guide bank guides the main flow into a restricted waterway; a marginal embankment keeps floodwater away from adjoining land. Their alignments and purposes are different.

8.2 Groynes and spurs

A groyne projects from the bank into the river. An impermeable groyne deflects the current strongly; a permeable groyne admits some flow, reduces local velocity and encourages deposition. Protect the nose and root against scour and outflanking.

Orientation in planUsual nameMain effect
Points upstreamRepellingDeflects flow away from the bank
Approximately normal to bankNormal or deflectingHolds/changes the local flow alignment
Points downstreamAttractingDraws the current towards the groyne line/bank

T-headed and hockey-shaped heads spread the protected zone. Submerged and non-submerged spurs behave differently during floods. A label alone is not a design: spacing, projection, angle, permeability and local sediment must work together. These functional distinctions follow the Central Water Commission river-protection handbook; numerical design dimensions are site-specific.

Plan-view groyne orientations with flow from left to right and one protected bank below.Plan-view groyne orientations with flow from left to right and one protected bank below.

8.3 Scour depth and protection datum

Past papers · CE 2020–2026 (14 papers): 1 question, 2 marks

The depth of scour below the present bed is present-bed elevation minus scour elevation, if positive. A general rule multiplying normal scour by the same factor everywhere is unsafe: bends, pier noses and groyne heads have different local effects. Use the factor supplied or the applicable design guidance.

Last-minute recall

  • High-water training concerns floods; low-water training concentrates low flow.
  • Guide banks and flood-excluding embankments have different jobs.
  • A repelling spur points upstream; an attracting spur downstream.
  • A launching apron is flexible scour protection.
  • Lacey grain diameter is in mm.
  • Normal scour depth is below flood water level, not below the existing bed.
  • Local maximum scour needs a stated local allowance.