Chapter 3

Gravity dams

A gravity dam resists water loading mainly through its own weight. Work with a unit-length section, draw every force and its line of action, then check sliding, overturning and contact pressure separately.

3.1 Loads and their lines of action

The heel is the upstream base edge; the toe is downstream. Use the base as elevation datum. Weight acts at the centroid of each concrete or masonry component. Include water resting on an inclined upstream face as a vertical load when applicable.

Uplift is upward and reduces the effective vertical load. Drainage can reduce uplift, but use a specified pressure diagram; do not assume zero uplift because drains exist. For a piecewise linear diagram, integrate each trapezoid and take its moment. Tailwater reduces net horizontal thrust but may increase uplift.

Dam force convention: upstream heel at the left, downstream toe at the right, and a separate uplift diagram.Dam force convention: upstream heel at the left, downstream toe at the right, and a separate uplift diagram.

3.2 Sliding, overturning and resultant

Past papers · CE 2020–2026 (14 papers): 1 question, 2 marks

A no-sliding limiting calculation sets available resistance equal to the driving force. It is not the same as meeting a design safety factor greater than one. Foundation shear strength, allowable stress and load combinations are inputs; no universal code factor is assumed here.

3.3 Base and face stresses

If ∣ed∣>bd/6|e_d|>b_d/6, the full-contact formula predicts tension and the no-tension criterion fails. A cracked-contact calculation requires a new compression zone and an appropriate uplift distribution; continuing with the same full-width triangle is not valid.

3.4 Elementary triangular section

Consider a triangular section of height HH with vertical upstream face, zero crest width, no tailwater, and water up to its top. This is a theoretical starting section, not a complete dam profile with roadway and freeboard.

The full-reservoir resultant reaches the downstream middle-third boundary at the no-tension width. With reservoir empty and uplift absent, the triangular section's weight acts at the upstream middle-third boundary. Practical crest width and additional loads change both results.

3.5 Additional loads and earthquake signs

Silt contributes effective lateral earth pressure in addition to the hydrostatic water pressure. Waves, ice where relevant, and earthquake inertia are separate loads; use supplied load diagrams rather than treating every load as hydrostatic.

For a specified hydrodynamic pressure distribution, integrate pressure over depth for resultant and moment; do not mix the resultant coefficient from one approximation with the centroid of another. Earth-pressure theory and stress transformation details: see the Geotechnical Engineering and Mechanics of Materials handbooks respectively.

Last-minute recall

  • Calculate forces per metre crest and moments about a named point.
  • Hydrostatic thrust varies as depth squared and acts at one-third depth from the base.
  • Uplift affects both vertical load and overturning moment.
  • Sliding, overturning and maximum compression are separate checks.
  • Positive ede_d increases toe compression.
  • The middle third is a no-tension condition for linear full contact.
  • Elementary-section limits exclude crest width and additional loads.
  • Dam-body inertia and reservoir hydrodynamic pressure are distinct.

Revise offline: the whole Irrigation Engineering handbook as one PDF

48 pages · 2.0 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections