Chapter 1

Catchment and water balance

Hydrology follows water through atmospheric, surface and subsurface stores. Fix the catchment boundary and time interval before adding depths or volumes; a transfer within the boundary is not an external loss.

1.1 Hydrologic cycle and accounting

Solar energy drives evaporation and transpiration; condensation and precipitation return water to land and water bodies. Water then moves through interception, depression storage, overland flow, infiltration, interflow, groundwater recharge and baseflow. A surface drainage divide need not coincide with a groundwater divide.

ConversionVolume
1 mm over 1 km2^210310^3 m3^3
1 cm over 1 km2^210410^4 m3^3
1 mm over 1 ha10 m3^3
1 m3^3/s maintained for 1 day86,400 m3^3

For a long period with negligible storage change and no external imports, precipitation is partitioned between ET and total runoff. Infiltration is a transfer into soil: do not subtract it again if soil and groundwater storage are already inside the balance.

1.2 Watershed response and geometry

Past papers · CE 2020–2026 (14 papers): 1 question, 1 mark

A watershed drains to one selected outlet. The time of concentration tct_c is the longest travel time from a contributing point to that outlet, not necessarily travel from the geometrically farthest point. An isochrone joins points with equal travel time.

Change, with other factors held fixedUsual hydrograph response
Greater drainage density or slopeEarlier, larger peak; shorter time base
Compact basin rather than elongated basinGreater synchronisation of arrivals; sharper peak
More impervious areaLess infiltration, more direct runoff, shorter lag
More detention storage or roughnessLower and later peak; longer recession
Wetter antecedent soilLess remaining storage; usually more runoff

Infiltration-excess runoff occurs when rain supply exceeds infiltration capacity. Saturation-excess runoff occurs when the soil store is full, even under modest rain. Direct runoff includes prompt interflow and rain on the channel; baseflow is the slower contribution. A gaining stream receives groundwater; a losing stream recharges it. Perennial streams flow throughout the year, intermittent streams flow seasonally, and ephemeral streams respond mainly to storms.

Last-minute recall

  • Choose the boundary before writing a balance.
  • Positive storage change means water accumulated.
  • Convert depths to volumes using the same catchment area.
  • Greater drainage density usually increases the peak and shortens the response.
  • Time of concentration is a travel time; lag to the hydrograph peak is a different quantity.
  • Direct runoff and surface runoff are not always identical.