Gradually varied flow and surface profiles
GVF describes a slowly changing depth while discharge remains constant. A profile label combines the slope category and the depth zone. Establish both before assigning a curve name or choosing an integration direction.
5.1 Slopes and the GVF equation
For constant , replace by in the depth equation. If varies, its derivative contributes too. A singular denominator near critical depth signals breakdown of the slowly varying approximation; it is not a physically vertical hydrostatic surface.
5.2 The twelve standard profiles
Past papers · CE 2020–2026 (14 papers): 2 questions, 2 marks
Compare normal and critical depths for the same discharge and section. Mild means (); steep means (). These are hydraulic categories, not visual judgements of bed angle.
| Profile | Depth range | Regime | Sign of |
|---|---|---|---|
| M1 | Subcritical | ||
| M2 | Subcritical | ||
| M3 | Supercritical | ||
| S1 | Subcritical | ||
| S2 | Supercritical | ||
| S3 | Supercritical | ||
| C1 | Subcritical | ||
| C3 | Supercritical | ||
| H2 | , | Subcritical | |
| H3 | , | Supercritical | |
| A2 | , | Subcritical | |
| A3 | , | Supercritical |
Zone 1 lies above both reference depths, zone 2 between them and zone 3 below both. On horizontal/adverse slopes normal depth is absent, so only zones 2 and 3 are used. C2 has zero depth interval. The signs assume the usual monotonic conveyance relation; compound critical-flow states need separate analysis.
Depth-zone paths calculated from the GVF equation for original mild and steep examples.
At normal depth a noncritical profile approaches uniform flow asymptotically. At very large depth with negligible and , , so the surface approaches horizontal. A smooth GVF solution cannot pass through a hydraulic jump. At critical slope, both numerator and denominator vanish at uniform critical depth; a limiting calculation is required rather than division by zero.
5.3 Controls and breaks in bed slope
Past papers · CE 2020–2026 (14 papers): 2 questions, 3 marks
A control supplies a depth–discharge relation. Subcritical flow responds to downstream control; supercritical flow responds to upstream control. Start a subcritical profile calculation downstream and march upstream; start a supercritical calculation upstream and march downstream.
| Situation, unchanged cross-section and discharge | Local profile logic |
|---|---|
| Mild reach approaching an unobstructed steep reach | M2 drawdown, a critical transition region, then S2 towards the steep normal depth |
| Steeper supercritical reach entering a less-steep but still steep reach | Incoming depth is below the new normal depth: S3 |
| Supercritical stream entering a mild reach | Initially M3; a jump may connect it to downstream subcritical flow |
| Mild reach controlled by a high downstream level | M1 backwater |
| Mild reach approaching a free overfall | M2 upstream; brink region is RVF, so critical depth is not simply the brink depth |
| Two mild slopes, second milder, downstream uniform control | M1 adjustment in the upstream reach towards the larger downstream normal depth |
Draw the bed, normal-depth lines and critical-depth line first. A change of slope alone does not change when geometry, discharge and correction factor stay fixed. A change of width does change it. Actual jump location also depends on reach lengths and boundary levels.
5.4 Computing profile length
Use small depth increments and check convergence by reducing the step. Near normal depth the direct-step denominator tends to zero, reflecting a long approach to uniform flow. Near critical depth the GVF assumptions fail. Standard-step calculations can use non-prismatic geometry when appropriate transition losses and end-section energy corrections are included.
Last-minute recall
- describes depth relative to the bed, not absolute water-surface elevation.
- Mild: ; steep: .
- S2 is supercritical; M2 is subcritical.
- Profiles numbered 1 or 3 increase in depth; profiles numbered 2 decrease.
- H1, A1 and C2 do not exist as finite depth zones.
- Integrate subcritical flow upstream and supercritical flow downstream from control.
- Direct step solves distance; standard step solves depth at a station.