Chapter 8

Flow past sharp-crested weirs

A sharp edge causes the overflow jet, or nappe, to separate from the plate. The measured head belongs to the undisturbed approach water surface. Free-flow ratings require an aerated nappe and sufficiently low downstream water level.

8.1 Head, nappe and valid operating conditions

Measure head hh vertically above the crest (or V-notch vertex), sufficiently upstream to avoid drawdown near the plate. Keep the crest horizontal, its upstream edge sharp, the plate vertical and the approach flow reasonably uniform. The underside of the free nappe must be ventilated to atmospheric pressure. Suppressed rectangular weirs span the full channel width; contracted weirs have side gaps that allow lateral contraction.

For standard contracted rectangular/Cipolletti installations, a measuring station at least four maximum heads upstream and bed/side clearances at least two maximum heads are conventional requirements. Calibration-specific limits still apply. A depressed or clinging nappe changes discharge at a given head; use a free-flow equation only when its operating conditions hold.

Original side view locating the upstream head and ventilated nappe.Original side view locating the upstream head and ventilated nappe.

8.2 Rectangular free weir

8.3 Triangular and trapezoidal openings

At small discharge a V-notch develops a larger measurable head than a wide rectangular weir and is useful over a broad flow range. The angle must be the included angle; for a 90∘90^\circ notch its half-angle tangent is 1. A trapezoidal opening can be integrated as a rectangle plus the two widening sides, but its real coefficient need not be identical for both contributions.

8.4 End contractions and standard empirical ratings

These are empirical free-flow ratings, not universal constants. A standard suppressed rectangular installation with full bottom contraction requires crest height at least three maximum heads above the approach bed. Use a fully developed, ventilated nappe, negligible approach velocity, adequate bottom/side clearance, and typically h/b≤1/3h/b\le1/3 for the standard contracted/Cipolletti range. Below roughly 0.06 m head, surface-tension/viscosity effects make the conventional standard rating unsuitable without specific calibration. The ideal triangular addition does not prove an exact compensation at every head; that compensation is empirical. Use a supplied CdC_d formulation instead when the question specifies it.

8.5 Approach velocity, sensitivity and submergence

At ha→0h_a\to0 the rectangular result is recovered. Do not replace hh by h+hah+h_a and forget the lower-limit subtraction under this strip model. Calibrated effective-head methods can use different conventions; follow the specified rating.

If tailwater submerges the nappe, discharge depends on both upstream and downstream levels and the free-weir rating is invalid. Use the stated submerged-weir relation and its calibration range; a universal percentage correction is not available. A sharp crest does not have the hydrostatic critical-depth section assumed for a broad-crested control, so y=2E/3y=2E/3 cannot be applied on its separated nappe.

Last-minute recall

  • Measure head above the crest, upstream of local drawdown.
  • A free rating requires an aerated nappe and low tailwater.
  • Rectangular discharge scales as h3/2h^{3/2}; V-notch discharge as h5/2h^{5/2}.
  • Use half the included V-notch angle inside the tangent.
  • Count contracted ends; do not correct the coefficient and length twice.
  • Cipolletti sides are 1 H:4 V and its SI standard coefficient is about 1.86.
  • Non-negligible approach velocity can make the discharge calculation implicit.
  • A submerged sharp-crested weir requires a suitable two-head calibration.

Revise offline: the whole Hydraulics handbook as one PDF

40 pages · 1.7 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections