Channel description and geometry
Start with the section and the type of variation. Geometry supplies three different lengths: flow depth, hydraulic depth and hydraulic radius. Substituting one for another changes both critical-flow and resistance calculations.
1.1 Channel and flow classification
A prismatic reach has unchanged cross-sectional shape, dimensions and bed slope along its length. A non-prismatic reach changes one or more of these. A rigid boundary retains its shape; an alluvial or mobile boundary can erode or deposit. A free surface is exposed to atmospheric pressure; a partly filled conduit can therefore carry open-channel flow.
| Classification | What is compared? | Useful example |
|---|---|---|
| Steady / unsteady | Conditions at one position do not change / change with time | Constant release / gate operation |
| Uniform / non-uniform | Depth and mean velocity do not change / change along the reach at an instant | Long constant-slope reach / backwater |
| Gradually varied flow (GVF) | Depth changes over a length much larger than depth | Backwater upstream of a control |
| Rapidly varied flow (RVF) | Depth changes over a short distance; vertical acceleration matters | Hydraulic jump, gate jet, weir nappe |
| Spatially varied discharge | Water is added or removed along the reach | Side inflow or lateral withdrawal |
Steadiness concerns time; uniformity concerns space. Do not identify the two definitions. In a fixed prismatic channel without lateral flow, continuity constrains any spatially uniform depth to be time-independent; uniform velocity can still change with time during an ideal acceleration.
1.2 Section properties
1.3 Standard round-bottom triangular section
CE past questions on round-bottom lined canals are counted in the Irrigation Engineering handbook, so the count shown here is lower than how often CE tests it.
A standard efficient round-bottom triangle joins a circular invert tangentially to two straight sides. The design waterline passes through the circle centre. This is not a sharp V-section with its corner merely omitted.
Original construction of a tangent-sided round-bottom section at its design depth.
1.4 Gravity and viscous regimes
| Number | Regimes and convention |
|---|---|
| Below 1: subcritical; 1: critical gravity-wave state; above 1: supercritical | |
| Common open-channel limits: below 500 laminar, 500–2000 transitional, above 2000 turbulent | |
| Same limits become 2000 and 8000; the characteristic length is four times larger |
Here is discharge (m/s), area (m), top width (m) and wetted perimeter (m). These Reynolds boundaries are approximate. Laminar/turbulent and subcritical/supercritical are independent classifications. The energy-minimum criterion with a specified is given in Section 3.2; do not silently mix corrected and uncorrected Froude definitions.
Last-minute recall
- Prismatic describes geometry; steady describes time variation.
- Wetted perimeter excludes the free surface.
- Resistance uses ; Froude number uses .
- A triangle has , not .
- Use radians in circular-segment geometry.
- In the standard rounded triangle, design depth equals radius and .