Chapter 1

Channel description and geometry

Start with the section and the type of variation. Geometry supplies three different lengths: flow depth, hydraulic depth and hydraulic radius. Substituting one for another changes both critical-flow and resistance calculations.

1.1 Channel and flow classification

A prismatic reach has unchanged cross-sectional shape, dimensions and bed slope along its length. A non-prismatic reach changes one or more of these. A rigid boundary retains its shape; an alluvial or mobile boundary can erode or deposit. A free surface is exposed to atmospheric pressure; a partly filled conduit can therefore carry open-channel flow.

ClassificationWhat is compared?Useful example
Steady / unsteadyConditions at one position do not change / change with timeConstant release / gate operation
Uniform / non-uniformDepth and mean velocity do not change / change along the reach at an instantLong constant-slope reach / backwater
Gradually varied flow (GVF)Depth changes over a length much larger than depthBackwater upstream of a control
Rapidly varied flow (RVF)Depth changes over a short distance; vertical acceleration mattersHydraulic jump, gate jet, weir nappe
Spatially varied dischargeWater is added or removed along the reachSide inflow or lateral withdrawal

Steadiness concerns time; uniformity concerns space. Do not identify the two definitions. In a fixed prismatic channel without lateral flow, continuity constrains any spatially uniform depth to be time-independent; uniform velocity can still change with time during an ideal acceleration.

1.2 Section properties

1.3 Standard round-bottom triangular section

CE past questions on round-bottom lined canals are counted in the Irrigation Engineering handbook, so the count shown here is lower than how often CE tests it.

A standard efficient round-bottom triangle joins a circular invert tangentially to two straight sides. The design waterline passes through the circle centre. This is not a sharp V-section with its corner merely omitted.

Original construction of a tangent-sided round-bottom section at its design depth.Original construction of a tangent-sided round-bottom section at its design depth.

1.4 Gravity and viscous regimes

NumberRegimes and convention
FrFrBelow 1: subcritical; 1: critical gravity-wave state; above 1: supercritical
ReRRe_RCommon open-channel limits: below 500 laminar, 500–2000 transitional, above 2000 turbulent
Re4RRe_{4R}Same limits become 2000 and 8000; the characteristic length is four times larger

Here QQ is discharge (m3^3/s), AA area (m2^2), TwT_w top width (m) and PwP_w wetted perimeter (m). These Reynolds boundaries are approximate. Laminar/turbulent and subcritical/supercritical are independent classifications. The energy-minimum criterion with a specified αk≠1\alpha_k\ne1 is given in Section 3.2; do not silently mix corrected and uncorrected Froude definitions.

Last-minute recall

  • Prismatic describes geometry; steady describes time variation.
  • Wetted perimeter excludes the free surface.
  • Resistance uses RhR_h; Froude number uses DmD_m.
  • A triangle has Dm=y/2D_m=y/2, not yy.
  • Use radians in circular-segment geometry.
  • In the standard rounded triangle, design depth equals radius and Rh=y/2R_h=y/2.

Revise offline: the whole Hydraulics handbook as one PDF

40 pages · 1.7 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections