Chapter 6

Subsurface investigation

Investigation establishes the stratigraphy, groundwater regime and parameters relevant to the proposed foundation. A test samples a finite soil volume; do not extend its result through an untested weak layer.

6.1 Boreholes and sampling

Past papers · CE 2020–2026 (14 papers): 4 questions, 4 marks

MethodUseful applicationLimitation to remember
Auger boringShallow exploration in soils that keep the hole openBelow-water loose sand may collapse; casing or hollow stem may be needed
Wash boringAdvance a cased hole using water circulationWashings do not preserve structure or precise thin-layer boundaries
Percussion drillingBreak hard material by repeated impactDisturbs material and may alter samples
Rotary drillingContinuous advance; core barrels in rockFluid and drilling disturbance affect recovered material
Thin-wall tube or piston samplerRelatively intact cohesive soil specimens“Undisturbed” is an aim; stress relief still occurs
Split-spoon samplerDisturbed samples with SPTSuitable for identification; not intact compressibility specimens

Record layer changes, recovery, water observations and sample depth on the bore log. Exploration must reach below significant foundation-induced stress and any suspect weak layer; a fixed multiple of footing width is not a universal stopping rule.

A Ménard pressuremeter expands a cylindrical cavity; a Marchetti flat dilatometer expands a membrane on a pushed blade. These provide in-situ deformation/stress information. Casagrande is associated with the liquid-limit test and Proctor with compaction. Electrical resistivity depends on electrode geometry, water and pore-fluid chemistry; no universal penetration depth is one-half of an arbitrary electrode spacing.

6.2 Standard and cone penetration tests

Past papers · CE 2020–2026 (14 papers): 3 questions, 3 marks

The current Indian test standard is IS 2131:2025, which supersedes IS 2131:1981. The conventional GATE procedure is summarised here; follow the edition and corrections named in the question. A 63.5 kg hammer falls 750 mm. The first 150 mm is seating; NN is the blow count for the following 300 mm. Obstruction or refusal must be reported with penetration rather than disguised as a normal N-value.

CPT gives near-continuous resistance but normally no sample. High tip resistance with low friction ratio often indicates granular soil; classification and strength correlations need the appropriate chart and local calibration. Gravel and cemented layers can obstruct penetration. A piezocone dissipation test tracks excess pore-pressure decay.

6.3 Plate load tests and size effects

Load a rigid plate at the proposed founding level in increments and record settlement. The load–settlement curve gives local response; a small plate may miss deep compressible strata and does not reproduce a large footing's consolidation time.

For an ideal surface footing in homogeneous sand, bearing capacity scales with width when the γBNγ\gamma BN_\gamma term governs. For undrained clay, net capacity is largely width-independent for similar shape. At depth, the surcharge term prevents a simple sand capacity ratio of Bf/BpB_f/B_p.

Last-minute recall

  • A borehole profile is essential context for a test value.
  • Small area ratio helps preserve a sample's structure.
  • SPT excludes the seating drive from N.
  • Energy correction multiplies N by the actual/reference energy ratio.
  • CPT friction ratio compares sleeve resistance with tip resistance in identical units.
  • A plate test can miss a weak layer reached by a wider foundation.

Revise offline: the whole Geotechnical Engineering handbook as one PDF

68 pages · 2.7 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections