Subsurface investigation
Investigation establishes the stratigraphy, groundwater regime and parameters relevant to the proposed foundation. A test samples a finite soil volume; do not extend its result through an untested weak layer.
6.1 Boreholes and sampling
Past papers · CE 2020–2026 (14 papers): 4 questions, 4 marks
| Method | Useful application | Limitation to remember |
|---|---|---|
| Auger boring | Shallow exploration in soils that keep the hole open | Below-water loose sand may collapse; casing or hollow stem may be needed |
| Wash boring | Advance a cased hole using water circulation | Washings do not preserve structure or precise thin-layer boundaries |
| Percussion drilling | Break hard material by repeated impact | Disturbs material and may alter samples |
| Rotary drilling | Continuous advance; core barrels in rock | Fluid and drilling disturbance affect recovered material |
| Thin-wall tube or piston sampler | Relatively intact cohesive soil specimens | “Undisturbed” is an aim; stress relief still occurs |
| Split-spoon sampler | Disturbed samples with SPT | Suitable for identification; not intact compressibility specimens |
Record layer changes, recovery, water observations and sample depth on the bore log. Exploration must reach below significant foundation-induced stress and any suspect weak layer; a fixed multiple of footing width is not a universal stopping rule.
A Ménard pressuremeter expands a cylindrical cavity; a Marchetti flat dilatometer expands a membrane on a pushed blade. These provide in-situ deformation/stress information. Casagrande is associated with the liquid-limit test and Proctor with compaction. Electrical resistivity depends on electrode geometry, water and pore-fluid chemistry; no universal penetration depth is one-half of an arbitrary electrode spacing.
6.2 Standard and cone penetration tests
Past papers · CE 2020–2026 (14 papers): 3 questions, 3 marks
The current Indian test standard is IS 2131:2025, which supersedes IS 2131:1981. The conventional GATE procedure is summarised here; follow the edition and corrections named in the question. A 63.5 kg hammer falls 750 mm. The first 150 mm is seating; is the blow count for the following 300 mm. Obstruction or refusal must be reported with penetration rather than disguised as a normal N-value.
CPT gives near-continuous resistance but normally no sample. High tip resistance with low friction ratio often indicates granular soil; classification and strength correlations need the appropriate chart and local calibration. Gravel and cemented layers can obstruct penetration. A piezocone dissipation test tracks excess pore-pressure decay.
6.3 Plate load tests and size effects
Load a rigid plate at the proposed founding level in increments and record settlement. The load–settlement curve gives local response; a small plate may miss deep compressible strata and does not reproduce a large footing's consolidation time.
For an ideal surface footing in homogeneous sand, bearing capacity scales with width when the term governs. For undrained clay, net capacity is largely width-independent for similar shape. At depth, the surcharge term prevents a simple sand capacity ratio of .
Last-minute recall
- A borehole profile is essential context for a test value.
- Small area ratio helps preserve a sample's structure.
- SPT excludes the seating drive from N.
- Energy correction multiplies N by the actual/reference energy ratio.
- CPT friction ratio compares sleeve resistance with tip resistance in identical units.
- A plate test can miss a weak layer reached by a wider foundation.