Stress distribution in soil
Foundation loading adds stress to the existing overburden. Use the added stress in settlement calculations and keep its reference depth at the load plane.
9.1 Boussinesq point load and pressure bulbs
Past papers · CE 2020–2026 (14 papers): 4 questions, 6 marks
Boussinesq's solution models a homogeneous, isotropic, linearly elastic, semi-infinite half-space with a horizontal surface. It gives load-induced stress; add initial stress separately. Vertical stress does not depend on elastic modulus or Poisson ratio in this solution.
A pressure bulb is a contour of equal stress increment, often expressed as a fraction of applied footing pressure. It is not a boundary beyond which stress becomes zero. At fixed nonzero , maximum point-load vertical stress occurs at , obtained by differentiating .
Point-load pressure bulbs use a reference length ell; contour values are dimensionless.
9.2 Distributed loads
Integrate the point-load kernel over the loaded area. The footing pressure may be uniform or spatially variable; do not apply a centre influence factor at a corner.
9.3 Strip load, charts and approximate spread
Scale the loaded plan to the chart's depth scale and place the evaluation point at its centre. Use the influence value printed with that chart; the number of sectors is not universal.
Last-minute recall
- Boussinesq stress is an increment above initial stress.
- Its vertical stress is independent of E and Poisson ratio.
- Superposition applies to loads in the linear elastic model.
- Circular and rectangular influence factors refer to a stated observation point.
- Strip-load angles in additive expressions must be in radians.
- The 2:1 approximation gives average stress over an expanding area.