Deep foundations
An axial pile transfers load by shaft resistance and toe resistance. A group can mobilise a different failure mechanism and settlement field from isolated piles, and soil settlement can add downward drag.
11.1 Static axial pile capacity
Past papers · CE 2020–2026 (14 papers): 5 questions, 9 marks
For a circular pile diameter and shaft length , and . Layer interfaces change the local shaft parameters; integrate over depth if stress varies continuously. The displayed is a net soil toe resistance convention. If a question defines gross toe resistance or includes pile self-weight and buoyancy, balance those explicitly to obtain the head load.
For straight-sided pile uplift without an enlarged base, neglect compressive toe resistance: net ultimate pullout resistance is . Add effective pile weight only for gross head pullout resistance, . Use uplift-calibrated shaft resistance ; it need not equal its compression value.
11.2 Groups, block failure and load sharing
Past papers · CE 2020–2026 (14 papers): 4 questions, 7 marks
For equal-diameter piles in a regular grid, and . Group settlement can govern even when its ultimate load capacity is adequate.
11.3 Pile load tests
IS 2911 (Part 4):2013 covers vertical compression, lateral and pull-out load tests. An initial test establishes load–displacement behaviour and design resistance; a routine test checks working piles. The loading schedule, displacement criterion and pile size must match the stated test specification.
A routine proof test is not automatically an ultimate-capacity test. Exclude reaction-system movement from measured pile-head displacement; unload–reload response helps distinguish recoverable and residual movement.
11.4 Lateral loading
A short stiff pile mainly rotates/translates; a long flexible pile bends and can form a plastic hinge. Head fixity changes both maximum moment and displacement. Soil resistance is nonlinear, so lateral ultimate capacity and working-load deflection are separate checks.
Use supplied Broms charts or p–y relations with their head condition, soil model and definitions. In a free head, rotation is allowed; in a fixed head it is restrained. A lateral head force applied above ground also produces a ground-line moment equal to force times its lever arm. Do not apply one head-condition coefficient to another.
11.5 Negative skin friction
When surrounding soil settles more than a pile, interface shear acts downward on the pile. Fill placement, groundwater lowering and consolidation of soft strata are common causes. The neutral plane is where pile and soil settlement are equal; axial pile load is often greatest there.
Last-minute recall
- Toe and shaft resistances have different areas and soil parameters.
- Installation affects adhesion and lateral stress around a pile.
- Check both individual-pile and group-block failure.
- Empirical efficiency does not replace group settlement analysis.
- Negative skin friction adds compression above the neutral plane.
- A free pile head and a fixed head have different lateral responses.
- Test acceptance criteria depend on the test type and pile geometry.