Chapter 11

Deep foundations

An axial pile transfers load by shaft resistance and toe resistance. A group can mobilise a different failure mechanism and settlement field from isolated piles, and soil settlement can add downward drag.

11.1 Static axial pile capacity

Past papers · CE 2020–2026 (14 papers): 5 questions, 9 marks

For a circular pile diameter dd and shaft length LpL_p, Ab=πd2/4A_b=\pi d^2/4 and As=πdLpA_s=\pi dL_p. Layer interfaces change the local shaft parameters; integrate over depth if stress varies continuously. The displayed QbQ_b is a net soil toe resistance convention. If a question defines gross toe resistance or includes pile self-weight and buoyancy, balance those explicitly to obtain the head load.

For straight-sided pile uplift without an enlarged base, neglect compressive toe resistance: net ultimate pullout resistance is Qu,net=∫fs,u dAsQ_{u,\rm net}=\int f_{s,u}\,dA_s. Add effective pile weight Wp′W'_p only for gross head pullout resistance, Qu,gross=Qu,net+Wp′Q_{u,\rm gross}=Q_{u,\rm net}+W'_p. Use uplift-calibrated shaft resistance fs,uf_{s,u}; it need not equal its compression value.

11.2 Groups, block failure and load sharing

Past papers · CE 2020–2026 (14 papers): 4 questions, 7 marks

For equal-diameter piles in a regular grid, Bg=(m−1)sp+dB_g=(m-1)s_p+d and Lg=(n−1)sp+dL_g=(n-1)s_p+d. Group settlement can govern even when its ultimate load capacity is adequate.

11.3 Pile load tests

IS 2911 (Part 4):2013 covers vertical compression, lateral and pull-out load tests. An initial test establishes load–displacement behaviour and design resistance; a routine test checks working piles. The loading schedule, displacement criterion and pile size must match the stated test specification.

A routine proof test is not automatically an ultimate-capacity test. Exclude reaction-system movement from measured pile-head displacement; unload–reload response helps distinguish recoverable and residual movement.

11.4 Lateral loading

A short stiff pile mainly rotates/translates; a long flexible pile bends and can form a plastic hinge. Head fixity changes both maximum moment and displacement. Soil resistance is nonlinear, so lateral ultimate capacity and working-load deflection are separate checks.

Use supplied Broms charts or p–y relations with their head condition, soil model and definitions. In a free head, rotation is allowed; in a fixed head it is restrained. A lateral head force applied above ground also produces a ground-line moment equal to force times its lever arm. Do not apply one head-condition coefficient to another.

11.5 Negative skin friction

When surrounding soil settles more than a pile, interface shear acts downward on the pile. Fill placement, groundwater lowering and consolidation of soft strata are common causes. The neutral plane is where pile and soil settlement are equal; axial pile load is often greatest there.

Last-minute recall

  • Toe and shaft resistances have different areas and soil parameters.
  • Installation affects adhesion and lateral stress around a pile.
  • Check both individual-pile and group-block failure.
  • Empirical efficiency does not replace group settlement analysis.
  • Negative skin friction adds compression above the neutral plane.
  • A free pile head and a fixed head have different lateral responses.
  • Test acceptance criteria depend on the test type and pile geometry.

Revise offline: the whole Geotechnical Engineering handbook as one PDF

68 pages · 2.7 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections