Distance and angle measurement
Separate instrument readings from geometrically reduced quantities. Correct the measuring device first, then reduce a slope measurement to horizontal and, if required, to the reference surface and map grid.
3.1 Tapes and length corrections
Past papers · CE 2020–2026 (14 papers): 1 question, 1 mark
A nominal tape length labels the graduations; actual length is the physical separation of those marks. A tape that is too long under-reports a ground distance, so its length correction is positive. Direct ranging aligns visible endpoints; reciprocal ranging uses intermediate points when endpoints are not mutually visible.
3.2 Slope and reference-surface reduction
Past papers · CE 2020–2026 (14 papers): 1 question, 1 mark
A gradient “1 in ” means vertical change divided by horizontal run is , unless the question explicitly says otherwise. Do not multiply a slope distance by an approximate slope factor when an exact right triangle is available.
3.3 EDM and total station reduction
A total station combines an electronic theodolite, electronic distance measurement (EDM) and computation/storage. It measures horizontal directions, vertical/zenith angles and usually slope distance; it computes coordinates after orientation and height entry. It does not independently know grid north or the height of its target.
Enter the appropriate atmospheric correction, prism constant and instrument/target heights. Prism constants are instrument/reflector dependent; their sign must come from the calibration convention. An accuracy expression corresponds to m, not an automatic independent-error root-sum-square.
3.4 Bearings, declination and local attraction
Past papers · CE 2020–2026 (14 papers): 5 questions, 5 marks
Whole-circle bearing (WCB) is measured clockwise from north in . Quadrantal/reduced bearing is an acute angle measured from N or S toward E or W. True, magnetic and grid bearings use different north references.
| Quadrantal bearing, | Whole-circle bearing |
|---|---|
| N E | |
| S E | |
| S W | |
| N W | (reduce 360° to 0°) |
A compass station error adds the same angular offset to all bearings observed at that station. Compare each forward/back pair, identify a trusted reference, then propagate corrections. A difference of proves equal station errors for that pair, not necessarily that both errors are zero. Angles between two directions observed at one station cancel a common magnetic station error.
3.5 Theodolite axes and face observations
Past papers · CE 2020–2026 (14 papers): 4 questions, 4 marks
Temporary adjustment: centre over the station, level the instrument, focus the eyepiece on cross hairs, then focus the object to remove parallax. A bubble tube senses inclination; a plumb bob or optical plummet centres; a tangent screw makes fine angular movements; stadia hairs measure a staff intercept.
| Fundamental relation | Why it matters |
|---|---|
| Plate-level axis perpendicular to vertical axis | Centred plate bubble makes the rotation axis vertical |
| Trunnion/horizontal axis perpendicular to vertical axis | Telescope rotates in a vertical plane |
| Collimation line perpendicular to trunnion axis | Sighting line sweeps the intended plane |
| Telescope altitude-level axis parallel to collimation line | When correctly adjusted, centred altitude bubble indicates horizontal sight |
| Vertical circle index correct at reference sight | Removes index offset; reference reading depends on angle convention |
Observe both faces to cancel first-order collimation, trunnion-axis and vertical-index effects under the corresponding adjustment model. Face reversal does not cure incorrect centring, an unlevelled vertical axis or changing refraction. Repetition accumulates one angle over several settings; reiteration measures multiple directions around a horizon and checks closure to .
For horizontal face readings, shift the reverse reading by , unwrap and average. For a repeated angle, divide the accumulated, unwrapped circle advance by the repetition count; do not discard whole revolutions.
3.6 Stadia and tangential tacheometry
Fixed stadia hairs intercept a larger staff length at a greater distance. Stadia formulas use paraxial optics and a small angle between the stadia rays; neglect curvature and refraction for these short sights. The staff orientation is part of the formula; the usual inclined-sight formula assumes a vertical staff.
If the staff is held perpendicular to the central line of sight, the centre-to-centre slope distance is ; its horizontal and vertical components use one cosine and one sine. This is not the vertical-staff formula.
Last-minute recall
- A long tape needs a positive calibration correction; sag correction is negative.
- Temperature rise lengthens the tape; more pull stretches it.
- Sag acts span by span and depends on the cube of unsupported span.
- Reduce corrected slope length to horizontal before plan-coordinate work.
- EDM time of flight is round-trip; divide by two.
- Zenith and elevation angles sum to .
- East-positive declination is added to magnetic bearing.
- A vertical staff in stadia surveying produces the term.
- Subtract target height when recovering ground RL.