Chapter 3

Distance and angle measurement

Separate instrument readings from geometrically reduced quantities. Correct the measuring device first, then reduce a slope measurement to horizontal and, if required, to the reference surface and map grid.

3.1 Tapes and length corrections

Past papers · CE 2020–2026 (14 papers): 1 question, 1 mark

A nominal tape length labels the graduations; actual length is the physical separation of those marks. A tape that is too long under-reports a ground distance, so its length correction is positive. Direct ranging aligns visible endpoints; reciprocal ranging uses intermediate points when endpoints are not mutually visible.

3.2 Slope and reference-surface reduction

Past papers · CE 2020–2026 (14 papers): 1 question, 1 mark

A gradient “1 in nn” means vertical change divided by horizontal run is 1/n1/n, unless the question explicitly says otherwise. Do not multiply a slope distance by an approximate slope factor when an exact right triangle is available.

3.3 EDM and total station reduction

A total station combines an electronic theodolite, electronic distance measurement (EDM) and computation/storage. It measures horizontal directions, vertical/zenith angles and usually slope distance; it computes coordinates after orientation and height entry. It does not independently know grid north or the height of its target.

Enter the appropriate atmospheric correction, prism constant and instrument/target heights. Prism constants are instrument/reflector dependent; their sign must come from the calibration convention. An accuracy expression ±(a mm+b ppm)\pm(a\text{ mm}+b\text{ ppm}) corresponds to ±(a×10−3+b×10−6L)\pm(a\times10^{-3}+b\times10^{-6}L) m, not an automatic independent-error root-sum-square.

3.4 Bearings, declination and local attraction

Past papers · CE 2020–2026 (14 papers): 5 questions, 5 marks

Whole-circle bearing (WCB) is measured clockwise from north in [0∘,360∘)[0^\circ,360^\circ). Quadrantal/reduced bearing is an acute angle measured from N or S toward E or W. True, magnetic and grid bearings use different north references.

Quadrantal bearing, 0≤β≤90∘0\le\beta\le90^\circWhole-circle bearing θ\theta
N β\beta Eβ\beta
S β\beta E180∘−β180^\circ-\beta
S β\beta W180∘+β180^\circ+\beta
N β\beta W360∘−β360^\circ-\beta (reduce 360° to 0°)

A compass station error adds the same angular offset to all bearings observed at that station. Compare each forward/back pair, identify a trusted reference, then propagate corrections. A difference of 180∘180^\circ proves equal station errors for that pair, not necessarily that both errors are zero. Angles between two directions observed at one station cancel a common magnetic station error.

3.5 Theodolite axes and face observations

Past papers · CE 2020–2026 (14 papers): 4 questions, 4 marks

Temporary adjustment: centre over the station, level the instrument, focus the eyepiece on cross hairs, then focus the object to remove parallax. A bubble tube senses inclination; a plumb bob or optical plummet centres; a tangent screw makes fine angular movements; stadia hairs measure a staff intercept.

Fundamental relationWhy it matters
Plate-level axis perpendicular to vertical axisCentred plate bubble makes the rotation axis vertical
Trunnion/horizontal axis perpendicular to vertical axisTelescope rotates in a vertical plane
Collimation line perpendicular to trunnion axisSighting line sweeps the intended plane
Telescope altitude-level axis parallel to collimation lineWhen correctly adjusted, centred altitude bubble indicates horizontal sight
Vertical circle index correct at reference sightRemoves index offset; reference reading depends on angle convention

Observe both faces to cancel first-order collimation, trunnion-axis and vertical-index effects under the corresponding adjustment model. Face reversal does not cure incorrect centring, an unlevelled vertical axis or changing refraction. Repetition accumulates one angle over several settings; reiteration measures multiple directions around a horizon and checks closure to 360∘360^\circ.

For horizontal face readings, shift the reverse reading by 180∘180^\circ, unwrap and average. For a repeated angle, divide the accumulated, unwrapped circle advance by the repetition count; do not discard whole revolutions.

3.6 Stadia and tangential tacheometry

Fixed stadia hairs intercept a larger staff length at a greater distance. Stadia formulas use paraxial optics and a small angle between the stadia rays; neglect curvature and refraction for these short sights. The staff orientation is part of the formula; the usual inclined-sight formula assumes a vertical staff.

If the staff is held perpendicular to the central line of sight, the centre-to-centre slope distance is Kss+CsK_s s+C_s; its horizontal and vertical components use one cosine and one sine. This is not the vertical-staff formula.

Last-minute recall

  • A long tape needs a positive calibration correction; sag correction is negative.
  • Temperature rise lengthens the tape; more pull stretches it.
  • Sag acts span by span and depends on the cube of unsupported span.
  • Reduce corrected slope length to horizontal before plan-coordinate work.
  • EDM time of flight is round-trip; divide by two.
  • Zenith and elevation angles sum to 90∘90^\circ.
  • East-positive declination is added to magnetic bearing.
  • A vertical staff in stadia surveying produces the cos⁡2α\cos^2\alpha term.
  • Subtract target height when recovering ground RL.

Revise offline: the whole Geomatics Engineering handbook as one PDF

49 pages · 2.1 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections