Chapter 12

Oblique shocks and expansion fansAE

A compression corner turns a supersonic stream toward itself and can create an oblique shock. An expansion corner turns it away and creates a continuous fan. Resolve shock-normal velocity before applying normal-shock formulas.

12.1 Oblique shocksAE

Past papers · AE 2020–2026 (7 papers): 6 questions, 10 marks

Here MM is total Mach number, MnM_n normal Mach number, γ=cp/cv\gamma=c_p/c_v, and VtV_t velocity tangent to the shock (m/s). Subscripts 1 and 2 mean immediately before and after the shock; p1,p2p_1,p_2 are static pressures (Pa).

For an attached compressive shock, sin⁡−1(1/M1)<βs≤90∘\sin^{-1}(1/M_1)<\beta_s\le90^\circ. Below the maximum allowable deflection there are weak and strong solutions; the weak solution has smaller βs\beta_s and is usually observed for an isolated wedge. Weak shocks may give subsonic downstream flow near detachment; do not assume they always leave M2>1M_2>1. Beyond the maximum deflection, the shock detaches and the attached-shock formula does not describe its full curved shape. At fixed βs\beta_s, increasing M1M_1 raises the allowable deflection toward a finite asymptote.

12.2 Prandtl–Meyer expansionAE

Past papers · AE 2020–2026 (7 papers): 2 questions, 4 marks

Here M1,M2M_1,M_2 are upstream/downstream Mach numbers, γ=cp/cv\gamma=c_p/c_v, pp static pressure (Pa), TT static temperature (K), and Θ(M)=1+(γ−1)M2/2\Theta(M)=1+(\gamma-1)M^2/2. Subscript 00 denotes local stagnation properties.

Fan rays make a Mach angle with the local flow, not with a fixed axis. If the incoming stream is horizontal and turns clockwise by θe\theta_e, the leading ray angle is μM1\mu_{M1} and the trailing ray angle is μM2−θe\mu_{M2}-\theta_e on the upper side. The fan spread is therefore μM1−μM2+θe\mu_{M1}-\mu_{M2}+\theta_e. Reverse the signed geometry for the opposite side.

A compression turn and an expansion turn use different wave constructions. Angles are measured from the stated flow direction.A compression turn and an expansion turn use different wave constructions. Angles are measured from the stated flow direction.

Last-minute recall

  • An oblique shock uses upstream normal Mach number.
  • Shock angle is measured from upstream velocity, not the wall normal.
  • Tangential velocity is unchanged; its Mach component changes.
  • Choose weak/strong branches using the physical boundary conditions.
  • A compression shock raises entropy; an ideal expansion fan does not.
  • Add flow turning to local Mach-line angles before measuring fan width.