Flow and pressure measurement
Measurements convert a pressure difference or local velocity into discharge. Keep the static pressure, stagnation pressure and hydrostatic elevation correction separate. A calibration coefficient corrects a specified ideal model; it is not universal.
10.1 U-tube manometers
Past papers · CE 2020–2026 (14 papers): 1 question, 1 mark
Here is pressure (Pa), elevation (m), gravity (m/s), and density of the liquid in step (kg/m).
A barometer gives , with vapour pressure above the column. A piezometer reads gauge pressure head for a liquid when the open column is physically possible.
10.2 Pitot and differential-pressure meters
Past papers · AE 2020–2026 (7 papers): 1 question, 2 marks · CE 2020–2026 (14 papers): 1 question, 2 marks · ME 2020–2026 (10 papers): 1 question, 2 marks
Here is fluid density (kg/m), gravity (m/s), static tap pressures (Pa), tap elevations (m), and discharge (m/s).
The Venturi expression is a continuity–Bernoulli application for all branches; AE's explicitly special instrument here is the Pitot probe. For compressible subsonic gas, use the isentropic relation of Chapter 11; at supersonic speed the probe's bow shock makes the measured total pressure lower than upstream total pressure (Section 11.4).
10.3 Orifices and draining tanks
Past papers · CE 2020–2026 (14 papers): 2 questions, 4 marks · ME 2020–2026 (10 papers): 2 questions, 3 marks
Here is gravity (m/s), are discharge/inflow (m/s), jet speed (m/s), and time (s).
10.4 Channel gauging and weirs
CE past questions on river discharge by the velocity–area method are counted in the Hydrology handbook, so the count shown here is lower than how often CE tests it.
Here is gravity (m/s), discharge (m/s), areas are in m, and all heads and widths are in m. is mean speed (m/s) in strip .
For a rectangular sharp-crested weir with appreciable approach speed , a common strip model replaces by , where ; solve consistently because depends on . If specified, the Francis end-contraction approximation uses effective crest width for contracted ends. Do not apply it to a suppressed weir. First-order head-reading error alone gives for rectangular and for V-notch discharge. A current meter uses its calibrated speed–rotation relation. Broad-crested controls, critical depth and hydraulic jumps belong to the Hydraulics handbook.
Last-minute recall
- Walk down a manometer column by adding .
- A differential manometer measures a piezometric-head difference.
- Pitot pressure is stagnation pressure; a static tap is different.
- Diameter ratio enters the meter denominator to the fourth power.
- Orifice coefficients obey under their stated definitions.
- Weir head is measured away from local drawdown.
- Depth fractions for current-meter readings are measured below the free surface.