Wastewater characterisation and sewerage
Wastewater calculations link flow, pollutant load and reaction time. Treat the sewer as a hydraulic conveyance system and the receiving stream as a separate mixing-and-reaction system.
4.1 Sewage quantity and population equivalent
Past papers · CE 2020–2026 (14 papers): 1 question, 2 marks
Domestic wastewater is the returned fraction of water consumption. Add industrial/commercial wastewater and infiltration/inflow separately. A separate sewer excludes intentional storm runoff; a combined sewer carries both. Partially separate systems admit selected runoff streams.
Fresh domestic sewage is usually grey; septic sewage becomes dark and sulphidic. Grab samples describe a particular time; a time composite averages sampling times and a flow-proportional composite represents daily load more directly. Do not average concentrations without considering sample weighting.
4.2 BOD measurement and kinetics
Past papers · CE 2020–2026 (14 papers): 4 questions, 7 marks
BOD measures oxygen consumed biologically during a specified incubation. Carbonaceous BOD excludes nitrification; total measured BOD can include it. Standard BOD₅ refers to five days at 20 °C; the Indian effluent convention also uses three days at 27 °C. These are distinct specified tests, not exactly equal by definition.
4.3 COD, TOC and nitrogen accounting
Past papers · CE 2020–2026 (14 papers): 6 questions, 11 marks
COD uses a chemical oxidant, conventionally dichromate; it includes oxidisable non-biodegradable matter. TOC is carbon mass, not oxygen mass. Usually COD exceeds BOD₅ for organic wastewater, but assay interferences, inhibition and nitrogenous BOD prevent treating this as a universal mathematical inequality. A low BOD₅/COD ratio suggests limited rapid biodegradability, not an absolute ban on biological treatment.
For complete nitrification add mg O₂ per mg ammonia-N, before biomass corrections. The oxygen equivalent of biomass is computed from its given empirical formula: C₅H₇O₂N gives g O₂/g biomass, but another biomass formula gives another factor. If yield is g biomass/g COD removed, the fraction of removed COD retained in biomass is times that oxygen-equivalent factor.
4.4 Mixing and ideal reactor balances
Past papers · CE 2020–2026 (14 papers): 2 questions, 4 marks
Write accumulation = inflow − outflow − disappearance. Conservative mixing has no reaction term. At a completely mixed splitter, each outlet has the same concentration; a splitter does not partition concentration in proportion to flow.
4.5 Stream oxygen deficit
Past papers · CE 2020–2026 (14 papers): 1 question, 1 mark
After instantaneous mixing, compute DO and ultimate BOD separately by flow-weighted balance. Let oxygen deficit be saturation DO minus actual DO. As carbonaceous BOD decays, oxygen consumption competes with reaeration.
Assumptions: steady uniform advection, constant saturation DO and coefficients, no additional loads, no sediment oxygen demand, no photosynthesis or nitrification term. At the critical point deoxygenation equals reaeration. If the model predicts negative DO, oxygen-limited behaviour invalidates its aerobic extrapolation.
Oxygen deficit rises then recovers while remaining BOD decays.
A nutrient-poor lake is oligotrophic; nutrient enrichment can drive eutrophication, algal blooms and subsequent oxygen depletion. Phosphorus and nitrogen are nutrients, not direct substitutes for BOD. Daytime photosynthesis can raise both DO and pH by generating oxygen and consuming CO₂.
4.6 Gravity sewer hydraulics
Select flow, diameter and slope together. Check self-cleansing at low flow and erosion/abrasion at high flow; a single design velocity cannot represent both. Detailed open-channel theory: see the Hydraulics handbook.
At half depth, speed equals full-flow speed and discharge is half the full-flow value. With constant , maximum speed occurs near and is about ; maximum discharge occurs near and is about . These maxima describe the free-surface mathematical model, not a recommendation to operate a sewer close to surcharge. Boundary shear for self-cleansing is ; check the required critical shear if given.
4.7 Sewer appurtenances and corrosion
Past papers · CE 2020–2026 (14 papers): 1 question, 1 mark
Manholes provide inspection and cleaning at junctions and changes of alignment, gradient or diameter. Drop manholes handle a large invert difference. Flushing devices clean low-velocity reaches. Inverted siphons are depressed pressure conduits beneath obstacles, not ordinary open-channel reaches. Storm inlets admit runoff; traps provide a water seal against sewer gases, and ventilation protects the seal and releases gases safely.
In anaerobic slime or sewage, sulphate-reducing bacteria generate sulphide. H₂S escapes to the headspace, dissolves in moisture at the crown and can be oxidised to sulphuric acid by sulphur-oxidising bacteria. Acid attacks concrete. This two-stage mechanism explains why sulphide generation and crown acid formation involve different microbial groups, as documented in the US EPA sewer corrosion design manual.
Last-minute recall
- Population equivalent is BOD mass load divided by per-person BOD load.
- Correct diluted BOD for the sample fraction and any specified seed demand.
- Natural-base and base-10 BOD rate constants differ by 2.303.
- Nitrogen ending as ammonia is not fully nitrified nitrogen.
- Balance DO and ultimate BOD independently at a confluence.
- Maximum oxygen deficit occurs where oxygen consumption equals reaeration.
- Half-full and full circular sewers have the same hydraulic radius.
- Sulphide production precedes sulphuric-acid attack at the sewer crown.