Chapter 7

Air pollution and control

Identify the pollutant, its formation route and the concentration basis before selecting control equipment. Ambient standards describe air people breathe; source-emission standards describe a discharge and may require temperature, moisture and oxygen corrections.

7.1 Pollutants, sources and effects

Past papers · CE 2020–2026 (14 papers): 5 questions, 6 marks

Primary pollutants are emitted directly; secondary pollutants form in the atmosphere. SO₂, CO, primary dust and emitted lead are primary examples. Ozone, PAN and much sulphate/nitrate aerosol are secondary examples. A pollutant such as NO₂ or particulate matter can have both direct and secondary contributions.

Pollutant/groupMain source or formationImportant impact
COIncomplete combustionCarboxyhaemoglobin reduces blood oxygen carriage
SO₂/SOₓSulphur-containing fuels and oresRespiratory irritation; acid deposition and material damage
NOₓHigh-temperature combustion; fuel nitrogenRespiratory effects; ozone and nitrate/acid precursors
PM₁₀/PM₂.₅Dust, combustion, secondary aerosolsRespiratory/cardiovascular harm; visibility loss
VOCsSolvents, fuels, industrial processesSome are toxic/carcinogenic; ozone precursors with NOₓ and sunlight
O₃ and PANPhotochemical reactionsOxidant injury to lungs, eyes and vegetation
LeadMetal processing and contaminated dustNeurological/developmental effects
NH₃Agriculture, wastes and some industryIrritation; secondary ammonium particles

Dust comes from mechanical breakup; fumes are fine solid particles formed by vapour condensation; smoke accompanies combustion. Mist and spray are liquid droplets; fly ash is solid combustion residue. PM size classes refer to aerodynamic diameter, not necessarily geometric diameter.

Photochemical smog needs NOₓ/VOC chemistry and sunlight; stagnation allows accumulation. Sulphurous smog is associated with smoke, SO₂ and cool humid conditions. Greenhouse gases absorb outgoing terrestrial long-wave radiation; much incoming short-wave solar radiation passes through. Stratospheric ozone protects against ultraviolet radiation, whereas ground-level ozone is a pollutant. Certain aromatic hydrocarbons are carcinogenic; oxidants such as ozone can cause cellular/genetic damage as well as respiratory irritation. Do not treat a matching question's health effect as the only effect of that pollutant.

7.2 Gas concentrations and emission corrections

Past papers · CE 2020–2026 (14 papers): 3 questions, 6 marks

For ideal gases, ppmv is mole fraction times one million. A ppmv value is not a mass concentration until molecular mass, temperature and pressure are known. “Normal” volume must specify its reference temperature and pressure.

At 25 °C and 1 atm, molar volume is about 24.45 L/mol, so Cmg/m3≃ppmvMg/24.45C_{\rm mg/m^3}\simeq\mathrm{ppmv}M_g/24.45. Convert mg/m³ to µg/m³ by multiplying by 1000. For particulate sampling, mass collected divided by sampled air volume gives concentration; correct blank mass and reference volume if specified.

7.3 Meteorology and dispersion

Past papers · CE 2020–2026 (14 papers): 3 questions, 5 marks

Define positive environmental lapse rate as temperature decrease with height: Γe=−dT/dz\Gamma_e=-dT/dz. Compare it with the dry adiabatic lapse rate Γd≃9.8\Gamma_d\simeq9.8 K/km for an unsaturated displaced parcel. For saturated parcels use the applicable moist adiabatic rate, which is not a universal constant.

Vertical structureStability/dispersion picture
Γe>Γd\Gamma_e>\Gamma_dUnstable; strong vertical mixing, looping possible
Γe=Γd\Gamma_e=\Gamma_dNeutral; coning is the conventional plume picture
Γe<Γd\Gamma_e<\Gamma_dStable relative to dry displacement; weak vertical mixing
Temperature rises with heightInversion, Γe<0\Gamma_e<0; strong stability and fanning
Stable layer below plume, mixed layer aboveLofting: downward spread restricted
Mixed layer below, stable cap aboveFumigation: strong downward transport, poor upward escape
Stable layers above and belowTrapping within an intervening layer

Night surface cooling can form radiation inversion; sinking air can create subsidence inversion. Mixing height bounds the layer available for dispersion. The dry-adiabatic line from the warmed surface and the observed temperature profile can estimate the daytime mixing height. These are idealised plume categories; real profiles can vary with height and time. See the NSW EPA meteorology guide.

At fixed dispersion lengths and effective height, concentration varies inversely with wind speed. The wind exponent is generally smaller in unstable than stable conditions for the same terrain. Increasing mixing height or wind improves the ventilation coefficient. Under the extra assumption that σy/σz\sigma_y/\sigma_z is constant as distance changes, centreline ground concentration peaks at σz=He/2\sigma_z=H_e/\sqrt2; it is not a universal maximum-location rule.

7.4 Pollution-control equipment

Past papers · CE 2020–2026 (14 papers): 7 questions, 10 marks

Capture first, then treat the captured stream. Fugitive emissions bypass the collector and remain emissions even when the downstream device has high removal efficiency.

Equipment/processSuitable targetOperating distinction
Gravity settling chamberCoarse dust, often a precleanerLow pressure drop; weak fine-particle capture
CycloneMedium/coarse particlesCentrifugal separation; no general gaseous-pollutant removal
Bag filterFine dry particlesFabric/dust cake capture; cleaning and temperature limits
Electrostatic precipitatorFine particles, including fly ashElectrical charging/migration; resistivity and re-entrainment matter
Wet/venturi scrubberParticles and suitable soluble/reactive gasesCreates liquid waste; high-energy venturi improves fine capture
Lime/limestone absorptionSO₂ and acid gasesGas–liquid reaction; reagent/sludge balance
AdsorptionSuitable VOCsFinite sorbent capacity; regeneration/replacement
Thermal/catalytic oxidationCO and combustible VOCsConverts rather than mechanically separates
Selective catalytic/non-catalytic reductionNOₓ using NH₃/ureaTemperature and reagent control

A coarse precollector before a fine collector reduces the fine unit's load. For a mixture of coarse 50 µm and fine 2 µm particles, a settling chamber followed by a bag filter is a sensible sequence. Flaring can oxidise a combustible CO-containing stream; catalytic conversion is also used for CO control.

7.5 National ambient air quality standards

Use India's NAAQS 2009, notified by CPCB on 18 November 2009. These ambient concentrations are different from stack limits and from AQI category cutoffs. The table gives industrial, residential, rural and other areas; the annual SO₂/NO₂ exceptions are stated below. Source: Government of India NAAQS table.

PollutantAnnual limitShort-period limit
PM₁₀, µg/m³60100, 24 h
PM₂.₅, µg/m³4060, 24 h
SO₂, µg/m³5080, 24 h
NO₂, µg/m³4080, 24 h
NH₃, µg/m³100400, 24 h
Pb, µg/m³0.51.0, 24 h
O₃, µg/m³—100, 8 h; 180, 1 h
CO, mg/m³—2, 8 h; 4, 1 h
Benzene, µg/m³5—
Benzo(a)pyrene, particulate phase, ng/m³1—
Arsenic, ng/m³6—
Nickel, ng/m³20—

For notified ecologically sensitive areas, annual SO₂ = 20 and NO₂ = 30 µg/m³. Annual means use at least 104 measurements taken twice weekly at uniform intervals. Applicable short-period limits must be met 98% of the year; allowed exceedances must not occur on two consecutive monitoring days. Do not mix ng/m³, µg/m³ and mg/m³.

7.6 Air quality index

India's AQI uses PM₁₀, PM₂.₅, NO₂, SO₂, CO, O₃, NH₃ and Pb. Compute individual subindices on the required averaging basis and select the largest; it is not their average. CPCB's national method requires sufficient valid data, including at least three pollutants with PM₁₀ or PM₂.₅ among them; a daily subindex generally needs at least 16 hours of observations.

CategoryAQI intervalMeaning for revision
Good0–50Least pollution burden
Satisfactory51–100Sensitive people may notice discomfort
Moderately polluted101–200Greater concern for susceptible groups
Poor201–300Prolonged exposure can affect more people
Very poor301–400Serious respiratory concern with exposure
Severe401–500Even healthy people can be affected

For rapid recall, the following are concentration upper boundaries at subindices 50, 100, 200, 300 and 400, transposed from CPCB's AQI documentation. The severe band begins above the last concentration shown. CO uses mg/m³; the others use µg/m³.

Pollutant50100200300400
PM₁₀, 24 h50100250350430
PM₂.₅, 24 h306090120250
NO₂, 24 h4080180280400
SO₂, 24 h40803808001600
NH₃, 24 h20040080012001800
Pb, 24 h0.51.02.03.03.5
CO, 8 h1.02.0101734
O₃50100168208748*

Ozone normally uses 8 h; the high-end starred ozone bands in CPCB's full table carry a 1 h monitoring qualification for mathematical calculation. Use the question's specified ozone basis. Published integer intervals such as PM₂.₅ 31–60 corresponding to 51–100 should be used literally when given, rather than silently replacing their lower endpoints by 30 and 50.

Last-minute recall

  • Primary/secondary describes formation, not toxicity or physical state.
  • Mist/spray are liquid; dust/fume/fly ash are solid.
  • Convert ppmv using absolute temperature and pressure.
  • More excess air lowers raw concentration; oxygen correction removes that dilution advantage.
  • Our lapse rate is −dT/dz-dT/dz; inversion gives a negative value.
  • Ventilation coefficient is wind speed times mixing height.
  • Collector efficiencies multiply through survival fractions.
  • Cloth out for cleaning is not operating cloth area.
  • NAAQS, emission limits and AQI breakpoints are three different tables.
  • AQI is the worst valid subindex, not the mean.

Revise offline: the whole Environmental Engineering handbook as one PDF

60 pages · 2.5 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections