Transmission lines and matching
Distributed lines carry forward and backward waves. Fix the coordinate before using a reflection phase. Here is the load, the line lies at , and current is positive towards the load; measures distance towards the generator.
7.1 Distributed model and characteristic impedance
Past papers · EC 2020–2026 (7 papers): 1 question, 2 marks
are series resistance (Ω/m), series inductance (H/m), shunt conductance (S/m) and shunt capacitance (F/m). A small length has series and shunt ; symmetric T and placements agree to first order in .
7.2 Load transformation and stubs
Past papers · EC 2020–2026 (7 papers): 2 questions, 2 marks
The load is (Ω). Input impedance is measured a distance towards the generator while looking towards that load. is wavelength on the line.
7.3 Reflection coefficient, standing waves and power
Past papers · EC 2020–2026 (7 papers): 3 questions, 6 marks
This section assumes a lossless line with real positive and a passive load. Let be voltage reflection coefficient, , and .
The load can be represented by a same- line section ending in or . For this equivalent network, compute reflection at its input as . Do not confuse this representation with moving a measurement plane in front of the original load.
Voltage standing-wave envelope versus distance towards the generator for an illustrative real positive load reflection coefficient.
7.4 Quarter-wave and single-stub matching
Past papers · EC 2020–2026 (7 papers): 1 question, 2 marks
A match means the input seen by the feeding line equals its real characteristic impedance. A reactive stub changes susceptance or reactance; it cannot independently change both parts at an arbitrary location.
7.5 Smith chart construction and movement
Past papers · EC 2020–2026 (7 papers): 2 questions, 3 marks
A Smith chart is the complex reflection-coefficient plane expressed in normalised impedance . Use as dimensionless values; normalised impedance has no Ω unit.
Selected constant-resistance and constant-reactance circles, drawn from the reflection mapping.
Last-minute recall
- Series and shunt are per unit length.
- Reflected current has the opposite sign in the travelling-wave expression.
- A half-wave repeats a load; an odd quarter-wave inverts it.
- Generatorward motion is clockwise under the stated convention.
- Standing-wave extrema are a quarter-wavelength apart.
- Delivered power is incident power times on a lossless line.
- Shunt matching uses admittance; series matching uses impedance.
- Normalised Smith-chart readings are dimensionless.