Chapter 7

Transmission lines and matchingEC

Distributed lines carry forward and backward waves. Fix the coordinate before using a reflection phase. Here z=0z=0 is the load, the line lies at z<0z<0, and current is positive towards the load; d=−z≥0d=-z\ge0 measures distance towards the generator.

7.1 Distributed model and characteristic impedanceEC

Past papers · EC 2020–2026 (7 papers): 1 question, 2 marks

R′,L′,G′,C′R',L',G',C' are series resistance (Ω/m), series inductance (H/m), shunt conductance (S/m) and shunt capacitance (F/m). A small length Δz\Delta z has series (R′+jωL′)Δz(R'+j\omega L')\Delta z and shunt (G′+jωC′)Δz(G'+j\omega C')\Delta z; symmetric T and π\pi placements agree to first order in Δz\Delta z.

7.2 Load transformation and stubsEC

Past papers · EC 2020–2026 (7 papers): 2 questions, 2 marks

The load is ZL=V(0)/I(0)Z_L=V(0)/I(0) (Ω). Input impedance is measured a distance dd towards the generator while looking towards that load. λ=2π/β\lambda=2\pi/\beta is wavelength on the line.

7.3 Reflection coefficient, standing waves and powerEC

Past papers · EC 2020–2026 (7 papers): 3 questions, 6 marks

This section assumes a lossless line with real positive Z0Z_0 and a passive load. Let ΓL\Gamma_L be voltage reflection coefficient, g=∣ΓL∣g=|\Gamma_L|, and ϕL=arg⁡ΓL\phi_L=\arg\Gamma_L.

The load can be represented by a same-Z0Z_0 line section ending in Zmax⁡Z_{\max} or Zmin⁡Z_{\min}. For this equivalent network, compute reflection at its input as Γterminale−j2βℓ\Gamma_{\rm terminal}e^{-j2\beta\ell}. Do not confuse this representation with moving a measurement plane in front of the original load.

Voltage standing-wave envelope versus distance towards the generator for an illustrative real positive load reflection coefficient.Voltage standing-wave envelope versus distance towards the generator for an illustrative real positive load reflection coefficient.

7.4 Quarter-wave and single-stub matchingEC

Past papers · EC 2020–2026 (7 papers): 1 question, 2 marks

A match means the input seen by the feeding line equals its real characteristic impedance. A reactive stub changes susceptance or reactance; it cannot independently change both parts at an arbitrary location.

7.5 Smith chart construction and movementEC

Past papers · EC 2020–2026 (7 papers): 2 questions, 3 marks

A Smith chart is the complex reflection-coefficient plane expressed in normalised impedance zn=Z/Z0=rn+jxnz_n=Z/Z_0=r_n+jx_n. Use rn,xnr_n,x_n as dimensionless values; normalised impedance has no Ω unit.

Selected constant-resistance and constant-reactance circles, drawn from the reflection mapping.Selected constant-resistance and constant-reactance circles, drawn from the reflection mapping.

Last-minute recall

  • Series R′,L′R',L' and shunt G′,C′G',C' are per unit length.
  • Reflected current has the opposite sign in the travelling-wave expression.
  • A half-wave repeats a load; an odd quarter-wave inverts it.
  • Generatorward motion is clockwise under the stated convention.
  • Standing-wave extrema are a quarter-wavelength apart.
  • Delivered power is incident power times 1−∣Γ∣21-|\Gamma|^2 on a lossless line.
  • Shunt matching uses admittance; series matching uses impedance.
  • Normalised Smith-chart readings are dimensionless.

Revise offline: the whole Electromagnetic Fields and Waves handbook as one PDF

52 pages · 2.2 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections