| Voltage/current, instantaneous; RMS/DC; phasor | v,i;V,I;V,I | V; A | RMS phasors throughout; subscripts identify winding/terminal/test |
| Time; frequency; electrical angular frequency | t;f;ω | s; Hz; rad/s | ω=2πf; j2=−1 |
| Rotor speed; synchronous speed | n,ns;ωm,ωs,m | rpm; rad/s | Mechanical angular speed; positive along chosen rotation |
| Pole count; electrical/mechanical angles | p;θe,θm,δe,δm | count; rad or explicitly degrees | p/2 pole pairs; load angle δ electrical unless stated |
| Load power-factor and impedance angles | ϕ,θZ | rad or explicitly degrees | ϕ=∠V−∠I; positive for lagging stated current |
| Flux, linkage, flux density; reluctance | Φ,Φm;ψe;Bm;Rm | Wb; Wb; T; A/Wb | Peak flux for sinusoidal emf; linkage includes turns |
| Induced emf, auxiliary internal emf | Ea,E,E0,Ek,E20,Eq′,Eℓ | V | RMS AC or DC; E20 standstill rotor value; Eq′ auxiliary salient phasor |
| Winding turns and transformer ratio | N1,N2,NH,NL;nt | count; 1 | nt=N1/N2 or HV/LV winding ratio; disambiguates circuit-handbook n from rpm |
| Effective induction turns ratio | nr | 1 | Stator/rotor phase effective turns, including winding factors |
| Resistance, reactance, impedance | R,X,Z;Ra,Rf,Rse,R1,R2;Rc,Xm | Ω | Physical or referred side explicitly specified; core resistance and magnetising reactance |
| Referred rotor and Thevenin parameters | R2′,X2′;RTh,XTh,VTh;XΣ,D | Ω; V for Thevenin voltage | XΣ=XTh+X2′; D=RTh2+XΣ2 |
| Self, leakage and mutual inductance | L,L1,L2,Lm,Lℓ,M | H | Position-dependent values in energy chapter; signed M fixed by dots |
| Power and apparent-power rating | P,Q,S,SN,Su | W; var; VA | Complex S=P+jQ; SN,Su positive rating magnitudes |
| Power-flow/loss subscripts | Pin,Pout,Pag,Pconv,Pcu,Prcu,Prot,Pcore,Pc | W | Input, output, air gap, converted, copper, rotor copper, rotational, core; Pc transformer constant core loss |
| Efficiency, regulation, loading fraction | η,VR,x | 1 | Multiply fractional efficiencies/regulations by 100 for percent |
| Base and per-unit values | Vb,Ib,Sb,Zb;Zpu | V; A; VA; Ω; 1 | Context-specific Vb also denotes DC brush-pair drop |
| Voltage tap and auto ratio | kv,k | 1 | kv reduced/rated motor voltage; k=VL/VH for autotransformer |
| Energy and coenergy; force | Wm,Wm′,Wmech;F | J; N | Reversible magnetic energy/coenergy; x is displacement in force derivative |
| Torque, inertia and load exponent | τe,τL,τloss,τshaft;J;r | N·m; kg·m²; 1 | Positive electromagnetic torque drives chosen angle; load resists |
| DC conductors, paths, winding multiplicity | Za,Aa,mw | counts | Avoid confusing Za conductor count with impedance |
| DC constant and field current | K,Km,Kb;If,Ise | Geometry factor; N·m/A; V·s/rad; A | K=pZa/(2πAa); constant-field Km=Kb=KΦ numerically in SI |
| Armature MMF and brush shift | Fa,pole,Fd,pole,Fc,pole;βe | A-turn/pole; electrical degrees | Total, demagnetising, cross component; positive demagnetising brush shift |
| Slip and rotor frequency | s,sf,sb,smax;f2,fslip | 1; Hz | Slip s is not the Laplace variable here; fslip=sf signed |
| No-load current components | Ic,Im,Iw,I0 | A | Core active, magnetising, total corrected active, no-load phase current |
| Single-phase auxiliary variables | IM,IA;αt,αs | A; rad | Main/auxiliary current; time/space displacement |
| Winding factors and geometry | kw,kp,kd,kp,h,kd,h;Tph,qs,Nslots;ϵ,β | 1; counts; electrical degrees | Pitch/distribution factors; turns/phase, slots/pole/phase, slot count; chording/slot angle |
| Harmonic order and vector clock | h | integer | Harmonic order in winding context; 0–11 clock number in vector-group context |
| Synchronous reactances and dq currents | Xs,Xd,Xq,Xℓ;Id,Iq | Ω; A | Synchronous, direct, quadrature, leakage/Potier; generator rotor-axis current convention in §7.4 |
| Field-current equivalents and relative phase | IfV,IfA,Ifℓ,If,ar;ψ | A; rad | OCC/SCC/Potier quantities defined in §7.5; ψ is not flux linkage ψe |
| Short-circuit ratio, stiffness, power-angle constants | SCR,Kδ;A,B | 1; W/electrical rad; W | P=Asinδ+Bsin2δ locally in salient model |
| Core-loss parameters | kh,ke,α,ah,ae;tlam,ρel | Model-dependent; m; Ω·m | Ph=khfBmα, Pe=kef2Bm2; Pcore/f=ah+aef |
| Temperature and resistance coefficient | T,T1,T2,αT1 | K or °C; K⁻¹ | Coefficient specified at reference temperature; differences equal in K and °C |
| General efficiency coefficients | a,b,c | W | Local model Pout=cx, Ploss=a+bx2 |
| Core area and allowed flux density | Acore,Ballowed | m²; T | Transformer core active area and specified peak flux-density limit |
| Integration variables and copper mass | ξ,ι;mCu | Wb; A; kg | Dummy linkage/current variables; copper-mass comparison in §2.5 |