Symbols and units

QuantitySymbolUnitConvention
Instantaneous voltage/current; DC or RMS magnitudesv,i;V,Iv,i;V,IV; AAC phasors are RMS; underlining marks complex phasors where needed
Resistance, impedance, inductance, mutual inductance, capacitanceR,Z,L,M,CR,Z,L,M,CΩ; Ω; H; H; FArm subscripts and physical connections are stated locally
Frequency, angular frequency, period, timef,ω,T,tf,\omega,T,tHz; rad/s; s; sω=2πf\omega=2\pi f; TT means waveform period here
Active/reactive/complex power and energyP,Q,S,EP,Q,S,EW; var; VA; J or kWhS=P+jQS=P+jQ where complex power is used; Q>0Q>0 inductive
Measured, indicated and reference valuesxi,xind,xref,yx_i,x_{\rm ind},x_{\rm ref},yMeasurand unitsGeneric scalar measurements
Signed error, correction, limiting bounde,c,δx,Δx,ϵe,c,\delta x,\Delta x,\epsilonMeasurand units; fractional ϵ\epsilonIndication minus reference; Δx≥0\Delta x\ge0
Full scale, range, maximum displayXFS,Xrange,Xmax⁡X_{\rm FS},X_{\rm range},X_{\max}Measurand unitsRange endpoint convention explicit
Sensitivity, uncertainty, scatterci,ui,uy,uxˉ,sx,U,kuc_i,u_i,u_y,u_{\bar x},s_x,U,k_u[y]/[xi][y]/[x_i]; input/output units; dimensionless kuk_ucic_i is a derivative; U=kuuyU=k_u u_y
Mean, covariance, repeated countxˉ,Cov⁡(xi,xj),n\bar x,\operatorname{Cov}(x_i,x_j),nInput units; product units; countsxs_x uses n−1n-1
Nonlinear-model parametersIs,a,VI_s,a,VA; V; Vaa is effective exponential voltage in 1.4
Decibel gain/lossGdB,LdBG_{\rm dB},L_{\rm dB}dBPositive attenuation loss
Pointer angle and torquesθ,Td,Tc,Tb,kθ,kg\theta,T_d,T_c,T_b,k_\theta,k_grad; N·m; N·m/rad for kθk_\thetaControlling and braking torques oppose motion/deflection
Magnetic field, coil area and turnsB,Ac,NB,A_c,NT; m²; turnsBB separately denotes an imaginary current component in 6.2
Movement, shunt and multiplierIfs,Rm,Rsh,Rmult,RA,RV,SV,mI,mVI_{\rm fs},R_m,R_{\rm sh},R_{\rm mult},R_A,R_V,S_V,m_I,m_VA; Ω; Ω/V for SVS_V; dimensionless ratiosFull-scale current; total ammeter/voltmeter input resistance
Meter inductances and extension capacitancesLm,Lsh,Cm,CsL_m,L_{\rm sh},C_m,C_sH; FMovement/shunt inductance; electrostatic range capacitors
Loading and ohmmeter parametersVTh,RTh,Ro,Eb,Itest,VsenseV_{\rm Th},R_{\rm Th},R_o,E_b,I_{\rm test},V_{\rm sense}V; Ω; A as appropriateThevenin source; internal ohmmeter resistance/battery
Form and crest factorsKf,KcK_f,K_c1KcK_c is a crest factor only in 2.4; transformer KcK_c is defined in 6.2
Bridge arms and detectorR1…R4,Z1…Z4,Rg,Ig,Sg,VBD,VsR_1\ldots R_4,Z_1\ldots Z_4,R_g,I_g,S_g,V_{BD},V_sΩ; A; rad/A; VDetector positive B to D; see each topology
Kelvin ratio/link resistancesP,Q,p,q,r,Rx,RsP,Q,p,q,r,R_x,R_sΩLocal resistor labels, not power; source A–D
Potentiometer standard and lengthsEs,Ex,E1,E2,ls,lx,l1,l2,kpE_s,E_x,E_1,E_2,l_s,l_x,l_1,l_2,k_pV; m; V/mkpk_p is voltage gradient; working current fixed
Cell/load and AC potentiometer componentsrcell,RL,loc,lload,Vd,Vqr_{\rm cell},R_L,l_{\rm oc},l_{\rm load},V_d,V_qΩ; m; VVd,VqV_d,V_q signed in-phase/quadrature voltages in 3.5
Coil/capacitor loss factorsQL,QC,D,δlossQ_L,Q_C,D,\delta_{\rm loss}1; radD=tan⁡δlossD=\tan\delta_{\rm loss}
Capacitor equivalent and standardRp,Cp,Cx,CsR_p,C_p,C_x,C_sΩ; FSeries-to-parallel conversion at stated frequency; probe parameters separately defined
Voltage-current phase and pressure-circuit lagϕ,ϕh,β\phi,\phi_h,\betarad or explicit degreesPositive ϕ\phi is lagging current
Wattmeter quantities and harmonic componentsW,Wa,Wb,Wc,Wq,Vpc,Icc,Vh,IhW,W_a,W_b,W_c,W_q,V_{\rm pc},I_{\rm cc},V_h,I_hW; V; ACoil polarities define sign; h=0h=0 is DC
Pressure/current-circuit parametersRpc,Lpc,Rcc,Vr,Ir,d,dfsR_{\rm pc},L_{\rm pc},R_{\rm cc},V_r,I_r,d,d_{\rm fs}Ω; H; V; A; divisionsScale dd is not CRT separation
Line/phase and three-meter readingsVline,Iline,Vs,VR,Vx,Is,IR,IxV_{\rm line},I_{\rm line},V_s,V_R,V_x,I_s,I_R,I_xV; AEach method defines the measured branch
Energy indication and constantsNE,KE,Kh,nrpm,ϵEN_E,K_E,K_h,n_{\rm rpm},\epsilon_Ecount; count/kWh; Wh/rev; rev/min; 1Count may mean pulses or disc revolutions
Induction-meter fluxes and speedΦv,Φi,Φb,Ωd,α,kd,kb\Phi_v,\Phi_i,\Phi_b,\Omega_d,\alpha,k_d,k_bWb; rad/s; rad; construction-dependent torque constantsα\alpha is voltage-to-pressure-flux lag
Transformer turns, burden and fluxNp,Ns,nc,nv,Sb,Zb,Es,Φmax⁡N_p,N_s,n_c,n_v,S_b,Z_b,E_s,\Phi_{\max}turns; 1; VA; Ω; V; WbCT nc=Ns/Npn_c=N_s/N_p; PT nv=Np/Nsn_v=N_p/N_s
Actual/nominal ratios, phase errorsRc,Rv,Kc,Kv,ϵr,βc,βv,RCFR_c,R_v,K_c,K_v,\epsilon_r,\beta_c,\beta_v,\mathrm{RCF}1; radians for phaseSecondary lead positive after polarity correction
Excitation and transformer dropsI0,Iw,Iμ,A,B,δ,Zp,Zs,ΔV‾I_0,I_w,I_\mu,A,B,\delta,Z_p,Z_s,\Delta\underline VA; rad; Ω; VA,BA,B real/imaginary primary-current components in 6.2
Digit/count specificationsd,Nmax⁡,Nspan,q,a,b,c,eq,uqd,N_{\max},N_{\rm span},q,a,b,c,e_q,u_qdigits; count; input units; percentage numbersqq least count; a,b,ca,b,c accuracy coefficients in 7.2
DVM integration and referenceT1,T2,N1,N2,Vref,fn,HT_1,T_2,N_1,N_2,V_{\rm ref},f_n,Hs; count; V; Hz; 1HH is boxcar gain at interference frequency
Counter gate and timebaseTg,N,Nc,m,fclk,fx,Tx,ϵtT_g,N,N_c,m,f_{\rm clk},f_x,T_x,\epsilon_ts; count; Hz; 1mm whole input cycles; one-count bound stated
Crossing delay and slopeΔt,Δterr,Δttrig,sv\Delta t,\Delta t_{\rm err},\Delta t_{\rm trig},s_vs; V/sCorresponding same-slope crossings
Oscilloscope scalesap,Sy,St,ny,nt,Vppa_p,S_y,S_t,n_y,n_t,V_{\rm pp}1; V/div; s/div; divisions; VProbe multiplier applied once
XY amplitudes, intercepts and phaseA,B,x,y,x0,y0,ψ,NH,NVA,B,x,y,x_0,y_0,\psi,N_H,N_VDisplay units; rad; countsψ\psi is Y minus X phase; tangent convention in 8.3
Probe and rise-time parametersRp,Ri,Cp,Ci,fBW,trR_p,R_i,C_p,C_i,f_{\rm BW},t_rΩ; F; Hz; sCompensated RC divider; 10–90% rise time
CRT and acquisitionVa,Vd,l,d,L,Le,y,Sd,fs,Ns,Δts,TrecordV_a,V_d,l,d,L,L_e,y,S_d,f_s,N_s,\Delta t_s,T_{\rm record}V; m; m/V; Hz; count; sLL measured from plate centre; NsN_s samples in 8.5, turns in 6.1

Revise offline: the whole Electrical and Electronic Measurements handbook as one PDF

48 pages · 2.0 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections