| Voltage and current | v, i; V, I | V; A | Lowercase instantaneous; uppercase DC, RMS phasors or Laplace transforms by context; transforms have V·s and A·s. |
| Element and terminal references | v_R, v_L, v_C, i_R, i_L, i_C; V_a, V_b | V; A | PSC for elements; node voltages relative to reference; terminal voltage V_a−V_b. |
| Resistance and equivalent resistance | R, r, R_s, R_p, R_seen, R_Th, R_L | Ω | Subscripts denote series, parallel, seen, Thevenin, load; r_L and r_C are component series losses. |
| Inductance, capacitance, mutual inductance | L, C, M; L_1, L_2; C_1, C_2 | H; F; H | Positive constant ideal element parameters; M≥0 with dot convention. |
| Charge and flux linkage | q_e, ψ_e; q_imp, ψ_imp | C; Wb (V·s) | Impulse areas produce state jumps; matches the charge/flux notation of the Control Systems handbook. |
| Power and stored energy | p, P, Q, S, w, E | W; W; var; VA; J; J | p instantaneous absorbed; P active; Q signed reactive; S complex; magnitude of S apparent. |
| Phasor magnitude and phase | V_m, I_m; θ, φ | V; A; rad or degrees | m denotes peak; φ=angle V−angle I; phasors are RMS. |
| Impedance and admittance | Z, Y; X, G, B | Ω; S; Ω; S; S | Z=R+jX, Y=G+jB; B also transmission impedance only inside ABCD context. |
| Port and source quantities | V_Th, V_oc, V_t, V_s, V_i, V_o; I_N, I_sc, I_t, I_L, I_s | V; A | I_t enters source network; I_L leaves it. s denotes source except for Laplace variable. |
| Controlled-source gains and controls | μ, r_m, g_m, β; v_x, i_x | 1; Ω; S; 1; V; A | VCVS, CCVS, VCCS, CCCS gains; signed control references. |
| Network indices and vectors | n, b, k, m; 𝐕, 𝐈, 𝐘 | count; V; A; S | n nodes, b branches; k,m local indices; bold matrices/vectors collect node quantities. |
| Wye/delta arm impedances | Z_a, Z_b, Z_c; Z_ab, Z_bc, Z_ca; Σ_Δ, K_Y | Ω; Ω; Ω; Ω² | Y product-sum K_Y; Δ side sum Σ_Δ; arm names redefined for T equivalent locally. |
| Time and switching quantities | t_0, t_x, Δt_k, T; τ, τ_k | s | T is delay or waveform period here, not temperature; τ is a circuit time constant. |
| Generic response and coefficients | x, x_0, x_∞, x_x, F_k, x_ss; d_0 | V or A; (V or A)/s | Initial, final, crossing, interval forced and sinusoidal particular values; d_0 initial slope. |
| Frequency and decay | f, ω, ω_0, ω_d, ω_r, ω_c, ω_L, ω_H, Δω, Δf; α, ζ | Hz; rad/s; s⁻¹; 1 | ω variants in rad/s; Δf in Hz; α decay rate, ζ damping ratio; critical frequency definitions local. |
| Complex frequency and residues | s, p_k; A_k, A_1, A_2 | s⁻¹; response units | s=σ_s+jω; p_k poles; residues A_k multiply exponentials (as in the Control Systems handbook). |
| Transfer response and denominator | H, D(s), X(s) | 1; 1; [x]·s | Voltage-ratio H; dimensionless RLC D(s); X is generic transform, not reactance in this context. |
| Quality factors | Q_f, Q_L, Q_C | 1 | Circuit quality distinct from reactive power Q; component factors evaluated at the stated frequency. |
| Compensation and power factor | Q_c, C_Y, C_Δ; pf, pf_true | var; F; 1 | Q_c positive supplied capacitive-var magnitude; bank capacitances are per phase. |
| Harmonic quantities | V_0, I_0, V_n, I_n, φ_n, V_rms, I_rms | V; A; rad or degrees | 0 denotes DC; n positive harmonic index; n-th phasors are RMS. |
| Two-port terminal quantities | V_1, V_2, I_1, I_2; Z_in, Z_out, Y_out, Z_s, Z_L, Y_s | V; A; Ω; S | Both port currents enter; source/load impedances retain Ω units; Y_s=1/Z_s. |
| Two-port parameter matrices | 𝐙, 𝐘, 𝐡, 𝐠; z_ij, y_ij, h_ij, g_ij | Ω; S; mixed | h11 Ω, h22 S; g11 S, g22 Ω; off-diagonal h/g dimensionless. |
| Transmission matrix | 𝐓; A, B, C_t, D | mixed; 1, Ω, S, 1 | [V1,I1]ᵀ=𝐓[V2,−I2]ᵀ; C_t is often printed C, distinct from capacitance. |
| Two-port determinants | Δ_z, Δ_y, Δ_h, Δ_g | Ω²; S²; 1; 1 | Determinants of the corresponding 2×2 parameter matrices; dagger denotes conjugate transpose. |
| Coupling and transformer ratio | k, n, N_1, N_2 | 1; 1; turns | k coupling coefficient; n=N1/N2 here, not node count; both currents enter dots. |
| Three-phase references | a,b,c,n,n′; V_an, V_bn, V_cn, V_ab, V_cb; I_a, I_ab, I_ca | labels; V; A | Source neutral n and load star point n′; positive sequence abc; delta current from first named node to second. |
| Three-phase power and line values | V_line, V_ph, V_phase; I_line, I_ph, I_phase; P_3φ, Q_3φ, S_3φ | V; A; W; var; VA | line and ph quantities are magnitudes; phase in complex-power product denotes matching phasors. |
| Wattmeter readings | W_a, W_c | W | Current coils a,c; voltage coils ab,cb; Q=√3(W_c−W_a) for balanced abc sequence. |
| Peak and initial values | V_f, V_0, V_1, V_2; t_v,pk, t_i,pk; ω_v,pk | V; s; rad/s | Charge-sharing initial/final voltages; current and capacitor-voltage peak times; capacitor frequency-response peak. |