Symbols and units

QuantitySymbolUnitNote
Voltage and currentv, i; V, IV; ALowercase instantaneous; uppercase DC, RMS phasors or Laplace transforms by context; transforms have V·s and A·s.
Element and terminal referencesv_R, v_L, v_C, i_R, i_L, i_C; V_a, V_bV; APSC for elements; node voltages relative to reference; terminal voltage V_a−V_b.
Resistance and equivalent resistanceR, r, R_s, R_p, R_seen, R_Th, R_LΩSubscripts denote series, parallel, seen, Thevenin, load; r_L and r_C are component series losses.
Inductance, capacitance, mutual inductanceL, C, M; L_1, L_2; C_1, C_2H; F; HPositive constant ideal element parameters; M≥0 with dot convention.
Charge and flux linkageq_e, ψ_e; q_imp, ψ_impC; Wb (V·s)Impulse areas produce state jumps; matches the charge/flux notation of the Control Systems handbook.
Power and stored energyp, P, Q, S, w, EW; W; var; VA; J; Jp instantaneous absorbed; P active; Q signed reactive; S complex; magnitude of S apparent.
Phasor magnitude and phaseV_m, I_m; θ, φV; A; rad or degreesm denotes peak; φ=angle V−angle I; phasors are RMS.
Impedance and admittanceZ, Y; X, G, BΩ; S; Ω; S; SZ=R+jX, Y=G+jB; B also transmission impedance only inside ABCD context.
Port and source quantitiesV_Th, V_oc, V_t, V_s, V_i, V_o; I_N, I_sc, I_t, I_L, I_sV; AI_t enters source network; I_L leaves it. s denotes source except for Laplace variable.
Controlled-source gains and controlsμ, r_m, g_m, β; v_x, i_x1; Ω; S; 1; V; AVCVS, CCVS, VCCS, CCCS gains; signed control references.
Network indices and vectorsn, b, k, m; 𝐕, 𝐈, 𝐘count; V; A; Sn nodes, b branches; k,m local indices; bold matrices/vectors collect node quantities.
Wye/delta arm impedancesZ_a, Z_b, Z_c; Z_ab, Z_bc, Z_ca; Σ_Δ, K_YΩ; Ω; Ω; Ω²Y product-sum K_Y; Δ side sum Σ_Δ; arm names redefined for T equivalent locally.
Time and switching quantitiest_0, t_x, Δt_k, T; τ, τ_ksT is delay or waveform period here, not temperature; τ is a circuit time constant.
Generic response and coefficientsx, x_0, x_∞, x_x, F_k, x_ss; d_0V or A; (V or A)/sInitial, final, crossing, interval forced and sinusoidal particular values; d_0 initial slope.
Frequency and decayf, ω, ω_0, ω_d, ω_r, ω_c, ω_L, ω_H, Δω, Δf; α, ζHz; rad/s; s⁻¹; 1ω variants in rad/s; Δf in Hz; α decay rate, ζ damping ratio; critical frequency definitions local.
Complex frequency and residuess, p_k; A_k, A_1, A_2s⁻¹; response unitss=σ_s+jω; p_k poles; residues A_k multiply exponentials (as in the Control Systems handbook).
Transfer response and denominatorH, D(s), X(s)1; 1; [x]·sVoltage-ratio H; dimensionless RLC D(s); X is generic transform, not reactance in this context.
Quality factorsQ_f, Q_L, Q_C1Circuit quality distinct from reactive power Q; component factors evaluated at the stated frequency.
Compensation and power factorQ_c, C_Y, C_Δ; pf, pf_truevar; F; 1Q_c positive supplied capacitive-var magnitude; bank capacitances are per phase.
Harmonic quantitiesV_0, I_0, V_n, I_n, φ_n, V_rms, I_rmsV; A; rad or degrees0 denotes DC; n positive harmonic index; n-th phasors are RMS.
Two-port terminal quantitiesV_1, V_2, I_1, I_2; Z_in, Z_out, Y_out, Z_s, Z_L, Y_sV; A; Ω; SBoth port currents enter; source/load impedances retain Ω units; Y_s=1/Z_s.
Two-port parameter matrices𝐙, 𝐘, 𝐡, 𝐠; z_ij, y_ij, h_ij, g_ijΩ; S; mixedh11 Ω, h22 S; g11 S, g22 Ω; off-diagonal h/g dimensionless.
Transmission matrix𝐓; A, B, C_t, Dmixed; 1, Ω, S, 1[V1,I1]ᵀ=𝐓[V2,−I2]ᵀ; C_t is often printed C, distinct from capacitance.
Two-port determinantsΔ_z, Δ_y, Δ_h, Δ_gΩ²; S²; 1; 1Determinants of the corresponding 2×2 parameter matrices; dagger denotes conjugate transpose.
Coupling and transformer ratiok, n, N_1, N_21; 1; turnsk coupling coefficient; n=N1/N2 here, not node count; both currents enter dots.
Three-phase referencesa,b,c,n,n′; V_an, V_bn, V_cn, V_ab, V_cb; I_a, I_ab, I_calabels; V; ASource neutral n and load star point n′; positive sequence abc; delta current from first named node to second.
Three-phase power and line valuesV_line, V_ph, V_phase; I_line, I_ph, I_phase; P_3φ, Q_3φ, S_3φV; A; W; var; VAline and ph quantities are magnitudes; phase in complex-power product denotes matching phasors.
Wattmeter readingsW_a, W_cWCurrent coils a,c; voltage coils ab,cb; Q=√3(W_c−W_a) for balanced abc sequence.
Peak and initial valuesV_f, V_0, V_1, V_2; t_v,pk, t_i,pk; ω_v,pkV; s; rad/sCharge-sharing initial/final voltages; current and capacitor-voltage peak times; capacitor frequency-response peak.

Revise offline: the whole Electric Circuits and Networks handbook as one PDF

49 pages · 2.1 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections