Symbols and units

SymbolMeaningUnit / convention
t,s,jt,s,jTime; Laplace variable; imaginary units; s−1^{-1}; j2=−1j^2=-1
r,e,u,yr,e,u,yReference, error, control input, outputPhysical signal units; uppercase for transforms
G,P,Cc,H,LG,P,C_c,H,LForward transfer, plant, controller, sensor, loopBlock output/input; L=GHL=GH dimensionless
S,TS,TSensitivity and complementary sensitivityDimensionless; S+T=1S+T=1
Du,Dy,ND_u,D_y,NInput disturbance, output disturbance, sensor noise transformsUnits of their summing nodes
K0,Kc,KK_0,K_c,KDC model gain; DC compensator gain; varied loop gainAs stated in each model
pi,zip_i,z_iPole and zero locationss−1^{-1}
ω,ωn,ωd\omega,\omega_n,\omega_dAngular, natural and damped frequenciesrad/s; ω=2πf\omega=2\pi f
ωr,ωBW\omega_r,\omega_{\mathrm{BW}}Resonant frequency and bandwidthrad/s
ωgc,ωpc\omega_{gc},\omega_{pc}Gain and phase crossover frequenciesrad/s
ζ,τ\zeta,\tauDamping ratio and time constantDimensionless; s
tr,tp,tst_r,t_p,t_sRise, peak and settling timess; definition and band must be specified
Mp,MrM_p,M_rFractional overshoot; resonant peak relative to DCDimensionless
σs,σ,σa\sigma_s,\sigma,\sigma_aReal part of ss; positive decay rate; root-locus centroids−1^{-1}; a decaying pole has σs=−σ\sigma_s=-\sigma
Kp,Kv,KaK_p,K_v,K_aStatic error constants1; s−1^{-1}; s−2^{-2}
ν\nuSystem typeNumber of loop origin poles
GM, PMGain and phase marginRatio or dB; degrees or radians as labelled
Ncw,P,ZN_{\mathrm{cw}},P,ZSigned encirclements, loop RHP poles, characteristic RHP zerosInteger counts in Chapter 7; PP elsewhere is plant
α,β\alpha,\betaLead and lag time-constant ratios0<α<10<\alpha<1, β>1\beta>1 in Chapter 9
kP,kI,kDk_P,k_I,k_DPID gains[u]/[e][u]/[e]; [u]/([e] s)[u]/([e]\,\mathrm{s}); [u] s/[e][u]\,\mathrm{s}/[e]
ZF,PF,NF,cwZ_F,P_F,N_{F,\mathrm{cw}}Zeros, poles and clockwise winding for a general contourInteger counts; Section 7.1
TI,TD,Tf,TdT_I,T_D,T_f,T_dIntegral, derivative, filter and delay timess
Kf,kfK_f,k_fState-feedback matrix; scalar state gainInput/state units; u=v−Kfxu=v-K_fx
x,A,B,C,D\mathbf x,A,B,C,DState vector and state matricesEntry-dependent units; see 10.1
Φ,T,C,O\Phi,T,\mathcal C,\mathcal OState transition, coordinate matrix, controllability and observability matricesMatrix meanings in Chapter 10; TT elsewhere is complementary sensitivity
f,q,xf,q,xApplied force, applied torque, displacementN; N·m; m; positive in the chosen motion direction
ve,ie,qe,ψev_e,i_e,q_e,\psi_eAnalogue voltage, current, charge, flux linkageV; A; C; Wb
bθ,kθb_\theta,k_\thetaRotational damping and torsional stiffnessN·m·s/rad; N·m/rad
m,b,k,Jm,b,k,JMass, viscous damping, stiffness, inertiakg; N·s/m; N/m; kg·m2^2
θ,qL,Km,Kb\theta,q_L,K_m,K_bShaft angle, load torque, motor torque and emf constantsrad; N·m; N·m/A; V·s/rad
KA,Kθ,Kt,Kact,KiK_A,K_\theta,K_t,K_{\mathrm{act}},K_iAmplifier, angle sensor, speed sensor, actuator and integrator gainsV/V; V/rad; V·s/rad; output/input; output/(input·s)
g,Nm,NLg,N_m,N_LGear speed ratio and tooth countsDimensionless; g=∣ωL/ωm∣g=\vert \omega_L/\omega_m\vert
ℓi,Pk,Δ,Δk\ell_i,P_k,\Delta,\Delta_kLoop gain, forward-path gain, graph determinant and cofactor1; output/input; 1; 1
R,L,CR,L,CResistance, inductance, capacitance in physical modelsΩ; H; F; distinguished from signal/block notation by context
ai,bia_i,b_iPolynomial or model coefficientsUnits fixed by each defining equation; indices are local