Chapter 7

Nyquist stability and stability marginsECEE

Nyquist uses the full loop frequency response to count closed-loop unstable poles. Margins quantify selected crossings, but a single gain or phase margin does not replace the encirclement test for a complicated loop.

7.1 Contour, direction and encirclementsECEE

Past papers · EC 2020–2026 (7 papers): 3 questions, 3 marks · EE 2020–2026 (7 papers): 4 questions, 5 marks

Let L(s)=G(s)H(s)L(s)=G(s)H(s) be the negative-feedback loop transfer. Traverse the boundary of the RHP clockwise: upward along the imaginary axis and back through the large right semicircle. Detour into the RHP around any poles on the imaginary axis, excluding them from the contour interior.

A supplied contour may detour into the LHP and include an axis pole. Then count that pole in PP and count the actual contour image. Do not substitute the usual RHP-only pole count. If the number of RHP zeros of LL is given instead of its poles, winding about 00 can first determine its pole count; winding about −1-1 then determines closed-loop RHP zeros. These are two different reference points.

If P=0P=0, stability requires no net encirclement of −1-1 and no passage through it. If P>0P>0, a stable closed loop needs PP net counterclockwise encirclements. A plotted positive-frequency branch is only part of the complete curve; for real coefficients, L(−jω)=L(jω)∗L(-j\omega)=L(j\omega)^*.

For a strictly proper rational loop, the large arc maps to the origin. For equal numerator and denominator degrees, it maps to their leading-coefficient ratio. For an improper loop, retain its high-frequency polynomial behaviour; a point at the origin is not justified. Near an origin pole of order ν\nu, L(s)∼k/sνL(s)\sim k/s^\nu: the small RHP detour maps to a large arc with an argument change −ν-\nu times the detour's argument change. Include that arc when counting.

A stable first-order loop and a loop with one unstable pole require different encirclement counts.A stable first-order loop and a loop with one unstable pole require different encirclement counts.

7.2 Gain margin, phase margin and delay marginECEE

Past papers · EC 2020–2026 (7 papers): 2 questions, 2 marks · EE 2020–2026 (7 papers): 2 questions, 4 marks

Use the loop transfer, including the feedback sensor, to read margins. Frequencies are positive; phase is unwrapped continuously using a branch compatible with the Nyquist curve.

With multiple crossings, evaluate every candidate and use the full Nyquist test to determine which boundary is destabilising. If no finite negative-real-axis crossing exists, the classical upper gain margin can be infinite; this alone does not prove stability. Positive PM and GM greater than one imply stability only with the usual open-loop-stable, ordinary single-crossing topology.

7.3 Second-order margin relationECEE

For one particular unity-feedback loop, damping and phase margin are linked exactly. Do not use the result for an arbitrary higher-order loop or a model with an extra zero.

Last-minute recall

  • Declare whether clockwise or counterclockwise turns are positive.
  • Count about −1-1 for the complete loop, including gain.
  • Open-loop RHP poles require stabilising counterclockwise turns in this convention.
  • Indent imaginary-axis poles; do not omit the image of the indentation.
  • Gain crossover is a magnitude condition; phase crossover is a phase condition.
  • Convert degrees to radians before calculating a delay in seconds.
  • Check every crossing when the curve is not a simple single-crossing loop.

Revise offline: the whole Control Systems handbook as one PDF

53 pages · 1.9 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections