Fluid-power actuators and electro-pneumatic automation
Identify the energy source, the valve state and the effective piston area before calculating motion. Pressure determines available force; flow and compressibility determine speed and response.
4.1 Actuator types and circuit elements
| System | Working medium and behaviour | Common use |
|---|---|---|
| Pneumatic | Compressed gas; compressible; exhaust usually returns to atmosphere | Rapid handling, gripping, short repetitive strokes |
| Hydraulic | Pressurised liquid; high stiffness relative to gas; fluid returns to a tank | Large forces, controlled feed, heavy loads |
| Electro-pneumatic | Electrical sensing/logic switches pneumatic valves | Sequenced cylinder operation with electrical control |
A single-acting cylinder powers one direction and returns by spring, gravity or external load. A double-acting cylinder powers both directions. A single-rod double-acting cylinder has unequal working areas; an equal-diameter double-rod cylinder has equal annular areas. Rotary actuators provide limited-angle rotation (vane or rack-and-pinion); fluid motors can rotate continuously.
| Component | Function |
|---|---|
| Compressor, receiver | Supply and store compressed air |
| Filter, regulator, lubricator (FRL) | Remove contamination; regulate downstream pressure; add lubricant only where required |
| Hydraulic pump and reservoir | Supply liquid flow; store and condition return fluid |
| Directional valve | Connect supply, actuator and return/exhaust paths |
| Relief valve | Limit maximum upstream pressure by opening a return path |
| Reducing valve | Maintain a lower downstream pressure; normally open in its controlled path |
| Check valve | Permit one-way flow |
| Throttle/flow control | Meter flow; a pressure-compensated unit reduces sensitivity to load pressure changes |
| Sequence valve | Open a path after a pressure threshold is reached |
| Counterbalance/pilot-operated check | Control an overrunning load or retain a load, according to circuit function |
| Accumulator | Store hydraulic energy in a compressed gas, spring or weight arrangement |
A pump primarily supplies flow; system resistance creates pressure. A relief setting is a limit, not a guarantee that every cylinder chamber is always at that pressure.
4.2 Cylinder areas and available force
Take positive motion as rod extension. Use gauge chamber pressures so atmospheric forces on the exposed rod are accounted for. Static pressure force is distinct from net force available to accelerate a load.
For dynamics, subtract any external resisting load from the available force and apply mass times acceleration. A spring-return actuator's spring assists one direction and opposes the other: assign its sign from the actual free-body diagram.
A single-rod cylinder with cap-side and rod-side areas labelled.
4.3 Flow, speed and air consumption
For a liquid with negligible compression and leakage, incoming volume equals the swept volume. For a gas, chamber pressure can change while air enters, so the same relation needs a constant-pressure approximation.
4.4 Directional valves and speed control
A designation such as 5/2 means five main ports and two positions. Each square in a directional-valve symbol is one position; arrows show connections and blocked ends show closed ports. Actuating symbols sit outside the squares. The square next to a spring shows the normal unactuated state.
| Valve | Typical task | Connection to check |
|---|---|---|
| 2/2 | Open or close a line | Two ports; no separate exhaust path |
| 3/2 | Single-acting pneumatic cylinder | Supply-to-actuator in one position; actuator-to-exhaust in the other |
| 4/2 | Double-acting actuator | Supply and return swap between two working ports |
| 5/2 | Double-acting pneumatic cylinder | Separate exhausts for the two working ports |
| 4/3 or 5/3 | Direction plus a centre state | Centre connections must be read from the symbol |
Use hydraulic labels P (supply), T (tank), A/B (actuator). Common pneumatic numbering is 1 supply, 2/4 working ports, 3/5 exhausts; use the drawing if it specifies a different assignment.
| Hydraulic 4/3 centre | Connections | Ideal consequence |
|---|---|---|
| Closed | All ports blocked | Actuator trapped; fixed-displacement pump needs a relief/unloading path |
| Open | P, T, A, B interconnected | Pump unloaded; actuator can float |
| Tandem | P to T; A/B blocked | Pump unloaded; actuator nominally held |
| Float | A/B to T; P blocked | Actuator can follow an external load; supply blocked |
Meter-in throttles fluid entering the actuator; it suits a resisting load but can lose control of an overrunning load. Meter-out throttles exhaust/return and develops back pressure, helping prevent runaway; it is commonly used on pneumatic cylinders. A one-way flow-control valve combines a throttle with a check-valve bypass. Bleed-off diverts part of pump flow to tank and cannot by itself restrain an overrunning load.
4.5 Hydraulic power and regenerative circuits
Hydraulic energy is pressure times displaced volume. Trace the complete return flow: recycling rod-side fluid changes the effective supply area and available force.
A gas-charged accumulator stores energy by compressing gas; use the specified gas process when calculating its pressure/volume change. A hydraulic intensifier uses force balance on linked unequal areas; it raises pressure while reducing delivered volume rate.
4.6 Rotary actuators and hydraulic motors
A positive-displacement pump converts shaft work into fluid power; a hydraulic motor does the reverse. A limited-angle rack-and-pinion actuator converts cylinder force to torque through the pinion pitch radius.
4.7 Electro-pneumatic switching and sequence
An electrical input may be a pushbutton, proximity sensor, pressure switch or end-position switch. A relay/PLC output energises a solenoid, which changes a directional valve's state. The air supplies the cylinder's mechanical energy; the electrical signal chooses the flow path.
For a monostable 5/2 valve, specify which position produces extension. A typical choice is coil on: supply to cap end and rod end to exhaust; coil off: spring return, supply to rod end and cap end to exhaust. For a bistable valve, a short pulse can select a position that persists after the pulse ends.
| Sequence notation | Meaning |
|---|---|
| ; | Cylinder A extends; retracts |
| ; | A retracted; extended end-position sensor |
| ; | Cylinder B extends; retracts |
| ; | B retracted; extended end-position sensor |
For , do not command B extension merely because A's solenoid was energised. Wait for , then command ; wait for before and before . End sensors confirm completion; a time delay alone does not prove the stroke occurred. Chapter 5 gives the corresponding state method.
A pneumatic shuttle valve implements an OR pressure signal. A two-pressure valve requires both inputs for an AND signal. Quick-exhaust valves vent near the cylinder to reduce exhaust restriction. Electrical interlocking prevents incompatible solenoid commands; valve type determines what “both commands off” actually does.
Last-minute recall
- Pneumatic compressibility affects motion; hydraulic liquid is treated as incompressible only in the ideal model.
- Cap area is full bore area; rod-side area is annular.
- Available cylinder force includes return-side pressure and opposing friction.
- Equal supply flow makes a single-rod cylinder retract faster than it extends.
- Use gauge pressure for actuator force and absolute pressure for air-volume conversion.
- Valve designation counts ports first and positions second.
- Read centre connections; the word “centre” alone does not define load behaviour.
- Regeneration uses rod area for both pump-flow balance and net force.
- Pump and motor volumetric efficiencies enter inverse relations.
- Sensors confirm motion; electrical commands only request it.