Transverse shear flow and shear centre
Transverse shear flow balances the change of axial force along the beam. Open contours have free-edge starting conditions; closed contours require additional circulatory flows. Obtain the shear centre by matching the torque of a zero-twist flow field to the moment of the applied transverse force.
3.1 Open-section shear flow
Choose a directed route from a free edge along the median line. For constant section geometry and no distributed applied couples, the resultant convention of Section 1.1 gives and .
This form assumes . If axial load is distributed into the walls, include directly in local longitudinal equilibrium. At a branch junction, algebraic flow into the junction equals flow out when no concentrated axial load is introduced there. Start each free branch independently, then combine the flows.
3.2 Boom shear-flow jumps
Between booms in a shear-only panel, axial stress is not assigned to the skin, so transverse shear flow is constant along that panel. At a boom, its changing axial force supplies a jump.
Check that the final free-edge flow returns to zero and that the resultant flows recover both imposed shear components. The zero return follows the centroid conditions ; it does not by itself check torque.
3.3 Shear-centre location
Past papers · AE 2020–2026 (7 papers): 3 questions, 4 marks
The shear centre is the point through which transverse shear causes no twist in elementary beam theory. It can lie outside the material. A symmetry axis contains the shear centre; two symmetry axes put it at their intersection. A thin angle with straight legs has its shear centre at their median-line intersection. A point-symmetric section also has its shear centre at the centre of symmetry.
A pure additional torque is independent of the origin. A shear-flow torque is origin-dependent because its resultant shear is nonzero. For open walls use the flexural shear flow from Section 3.1; for closed walls impose zero twist as in Section 3.4 first.
Channel shear centre lies outside the web; both flanges extend towards positive y.
3.4 Single-cell closed-section shear
Make a mathematical cut in the closed contour and calculate an open-section basic flow using Section 3.1, or boom jumps. Restore closure by adding a constant circulatory flow . Use positive circulation such that .
3.5 Multicell transverse shear
Cut one independent wall per cell to obtain a contour network without closed loops. Calculate the basic flow, then add one unknown circulation for each cell. All cell circulations use the same positive rotational sense. A wall shared by cells receives in the direction of cell .
The shared wall enters two compatibility equations with opposite orientation, but is counted only once as physical material when computing energy or resultant forces. A different artificial-cut choice changes the basic and closing flows separately, not their sum.
Last-minute recall
- Open-wall flow starts from zero at an unloaded free edge.
- Branch flows obey longitudinal force balance at junctions.
- Boom-only axial models give constant flow between booms.
- Verify both force resultants before using the flow moment.
- Closed cells need circulation constants in addition to the basic flow.
- Zero twist means in each cell.
- Common-wall circulations subtract.
- The centroid and shear centre answer different questions.