Chapter 9

Turbine blade cooling

Cooling permits the gas temperature to exceed the acceptable metal temperature. Compressor bleed supplies most conventional air-cooling schemes, so thermal protection costs compression work, useful core flow and mixing performance. Detailed compressor–turbine matching belongs to Turbomachinery.

9.1 Cooling mechanisms and coolant accounting

MethodMechanism and limitation
Internal convectionCoolant flows through passages; ribs and turns can increase heat transfer but also pressure loss.
ImpingementCoolant jets strike an internal wall; useful where local heat load is high, including the leading edge.
Film coolingCoolant exits through holes/slots and forms a surface layer; attachment and coverage matter.
Transpiration coolingCoolant passes through a porous surface for distributed protection; manufacturing and blockage are concerns.
Thermal barrier coatingLow-conductivity coating adds thermal resistance; it complements cooling and is not a coolant stream.

Film coolant is usually cooler than the mainstream, but warmer than the ambient inlet air after compression. More coolant does not automatically improve total engine efficiency; excessive blowing can also lift a film from the surface. Cooling of rotating blades and stationary vanes uses related mechanisms with different passage constraints.

If a fraction βc\beta_c of compressor inlet air bypasses the burner for cooling, burner air is (1−βc)m˙a(1-\beta_c)\dot m_a. A burner-defined fuel ratio fbf_b then corresponds to an engine-inlet ratio f=(1−βc)fbf=(1-\beta_c)f_b. If all coolant rejoins before the section being analysed, its total flow is (1+f)m˙a(1+f)\dot m_a; otherwise use the actual flow at each turbine section. Mixing enthalpy, not simply temperature, is conserved.

Original cooling-path schematic: internal convection, wall conduction and an external film act at different locations.Original cooling-path schematic: internal convection, wall conduction and an external film act at different locations.

9.2 Metal temperature and cooling effectiveness

Let TgT_g be the hot-side gas reference temperature, Tc,inT_{c,\rm in} coolant inlet temperature and TmT_m metal temperature. In high-speed heat-transfer problems the reference is the stated recovery/adiabatic-wall temperature, not automatically static or total gas temperature. The definitions below use the same reference consistently.

Last-minute recall

  • Blade cooling is an AE special topic.
  • Gas temperature and metal temperature are different design limits.
  • Internal convection removes heat; a film also changes the hot-side thermal boundary.
  • An adiabatic film effectiveness is not an overall metal cooling effectiveness.
  • Compressor bleed carries a cycle penalty and changes burner air flow.
  • Add coolant mass and enthalpy only at the section where it rejoins.
  • Coating, wall and convection resistances add in a one-dimensional series model.