Turbine blade cooling
Cooling permits the gas temperature to exceed the acceptable metal temperature. Compressor bleed supplies most conventional air-cooling schemes, so thermal protection costs compression work, useful core flow and mixing performance. Detailed compressor–turbine matching belongs to Turbomachinery.
9.1 Cooling mechanisms and coolant accounting
| Method | Mechanism and limitation |
|---|---|
| Internal convection | Coolant flows through passages; ribs and turns can increase heat transfer but also pressure loss. |
| Impingement | Coolant jets strike an internal wall; useful where local heat load is high, including the leading edge. |
| Film cooling | Coolant exits through holes/slots and forms a surface layer; attachment and coverage matter. |
| Transpiration cooling | Coolant passes through a porous surface for distributed protection; manufacturing and blockage are concerns. |
| Thermal barrier coating | Low-conductivity coating adds thermal resistance; it complements cooling and is not a coolant stream. |
Film coolant is usually cooler than the mainstream, but warmer than the ambient inlet air after compression. More coolant does not automatically improve total engine efficiency; excessive blowing can also lift a film from the surface. Cooling of rotating blades and stationary vanes uses related mechanisms with different passage constraints.
If a fraction of compressor inlet air bypasses the burner for cooling, burner air is . A burner-defined fuel ratio then corresponds to an engine-inlet ratio . If all coolant rejoins before the section being analysed, its total flow is ; otherwise use the actual flow at each turbine section. Mixing enthalpy, not simply temperature, is conserved.
Original cooling-path schematic: internal convection, wall conduction and an external film act at different locations.
9.2 Metal temperature and cooling effectiveness
Let be the hot-side gas reference temperature, coolant inlet temperature and metal temperature. In high-speed heat-transfer problems the reference is the stated recovery/adiabatic-wall temperature, not automatically static or total gas temperature. The definitions below use the same reference consistently.
Last-minute recall
- Blade cooling is an AE special topic.
- Gas temperature and metal temperature are different design limits.
- Internal convection removes heat; a film also changes the hot-side thermal boundary.
- An adiabatic film effectiveness is not an overall metal cooling effectiveness.
- Compressor bleed carries a cycle penalty and changes burner air flow.
- Add coolant mass and enthalpy only at the section where it rejoins.
- Coating, wall and convection resistances add in a one-dimensional series model.