Surface loads and moment reference points
Pressure and tangential traction provide the aerodynamic resultant. A change of reference point changes its moment but not its force. The aerodynamic centre and centre of pressure answer different questions.
2.1 Surface traction and pressure coefficient
Past papers · AE 2020–2026 (7 papers): 2 questions, 3 marks
Pressure acts into the body, opposite the outward normal. Wall shear acts tangentially. Geometry and these surface distributions are sufficient to calculate forces and moments without knowing the freestream state.
At an incompressible stagnation point, ; a suction region has . The incompressible value 1 is not the compressible stagnation-pressure coefficient. Pressure-coefficient plots often reverse the vertical scale, putting negative suction values at the top; read the labels.
2.2 Section loads from pressure
For this section only, runs aft along the chord and upward; the freestream vector makes angle to . Upper and lower surfaces are and . Let be upward chord-normal force and aft-positive chord-axial force per span; neither is automatically lift or drag.
2.3 Moving the moment reference
Changing the reference point cannot change the physical load. Use the chord-normal force for exact chordwise transfers; replace it by lift only in the small-angle thin-section approximation.
2.4 Aerodynamic centre and centre of pressure
Past papers · AE 2020–2026 (7 papers): 1 question, 2 marks
The aerodynamic centre (AC) is the location where moment is independent of angle of attack in the stated linear-flow regime. Its moment need not vanish. The centre of pressure (CP) is where the force resultant has zero moment. It generally moves as incidence changes.
At zero lift a cambered airfoil can retain a pitching couple, so a finite CP is undefined. For a symmetric thin airfoil with nonzero lift, AC and CP are both at quarter chord. At zero lift and zero moment the zero resultant has no unique application point. For a conventional positively cambered airfoil, the quarter-chord moment is usually negative; reflex camber can change that sign.
Last-minute recall
- Pressure is normal traction; skin friction is tangential traction.
- Loads require surface distributions; coefficients additionally require reference scales.
- uses freestream dynamic pressure, not local dynamic pressure.
- Integrate the lower-minus-upper pressure coefficient to obtain thin-section lift.
- Aft upward loading produces a nose-down moment about LE.
- Moving the reference aft adds normal force times the aft displacement.
- AC means constant moment; CP means zero moment.
- A zero-lift pitching couple has no finite CP.